High-throughput assay for simultaneous quantification of the plasma concentrations of morphine, fentanyl, midazolam and their major metabolites using automated SPE coupled to LC–MS/MS
Authors:
- Sussan GhassabianSGSussan Ghassabian
- Seyed Mojtaba MoosaviSMSeyed Mojtaba Moosavi
- Yarmarly Guerra ValeroYVYarmarly Guerra Valero
- Kiran ShekarKSKiran Shekar
- John F. FraserJFJohn F. Fraser
- Maree T. SmithMSMaree T. Smith
- 1 August 2012
- journal article
- research article
- Published by Elsevier in Journal of Chromatography B
- Vol. 903, 126-133
Abstract
No abstract availableKeywords
This publication has 24 references indexed in Scilit:
- Online extraction LC–MS/MS method for the simultaneous quantitative confirmation of urine drugs of abuse and metabolites: Amphetamines, opiates, cocaine, cannabis, benzodiazepines and methadoneJournal of Chromatography B, 2011
- Sensitive determination of a pharmaceutical compound and its metabolites in human plasma by ultra-high performance liquid chromatography–tandem mass spectrometry with on-line solid-phase extractionJournal of Pharmaceutical and Biomedical Analysis, 2011
- A High-Throughput Assay Using Liquid Chromatography-Tandem Mass Spectrometry for Simultaneous In Vivo Phenotyping of 5 Major Cytochrome P450 Enzymes in PatientsTherapeutic Drug Monitoring, 2009
- High-Speed Simultaneous Determination of Nine Antiepileptic Drugs Using Liquid Chromatography-Mass SpectrometryTherapeutic Drug Monitoring, 2008
- Fully Automated Determination in the Low Nanogram per Liter Level of Different Classes of Drugs of Abuse in Sewage Water by On-Line Solid-Phase Extraction-Liquid Chromatography−Electrospray-Tandem Mass SpectrometryAnalytical Chemistry, 2008
- High-throughput on-line solid-phase extraction–liquid chromatography–tandem mass spectrometry method for the simultaneous analysis of 14 antidepressants and their metabolites in plasmaJournal of Chromatography A, 2007
- Liquid Chromatography–Tandem Mass Spectrometry for Detection of Low Concentrations of 21 Benzodiazepines, Metabolites, and Analogs in Urine: Method with Forensic ApplicationsClinical Chemistry, 2006
- Simultaneous determination of morphine, oxycodone, morphine-3-glucuronide, and noroxycodone concentrations in rat serum by high performance liquid chromatography–electrospray ionization–tandem mass spectrometry☆Journal of Chromatography B, 2005
- Determination of morphine and morphine glucuronides in human plasma by 96-well plate solid-phase extraction and liquid chromatography–electrospray ionization mass spectrometryJournal of Chromatography B, 2003
- Simultaneous assay of morphine, morphine-3-glucuronide and morphine-6-glucuronide in human plasma using normal-phase liquid chromatography–tandem mass spectrometry with a silica column and an aqueous organic mobile phaseJournal of Chromatography B: Biomedical Sciences and Applications, 1999