Oxazolochlorins 11: Tuning the dynamic high pH sensing range of [meso-tetraarylporpholactonato]M(II) complexes by variation of the central metal ion, the aryl substituents, and introduction of a β-nitro group
- 29 August 2013
- journal article
- research article
- Published by World Scientific Pub Co Pte Ltd in Journal of Porphyrins and Phthalocyanines
- Vol. 17 (08n09) , 836-849
Abstract
Based on the high pH-sensing ability of [meso-tetrakis(pentafluorophenyl) porpholactonato]-platinum(II), we investigated the influence of the metal ( M = Zn ( II ), Ni ( II ), Cu ( II ), Pd ( II ), Ag ( II ), Pt ( II )), the aryl group ( Ar = C 6 H 5, C 6 F 5), and the presence of a β- NO 2 group on the pH sensing range. The syntheses of the novel β-nitroporpholactone derivatives are described, and their regiochemistry deduced by spectroscopic and single crystal X-ray diffraction methods. The UV-vis base titration midpoints for all derivatives were determined in an aqueous solution containing a surfactant, showing that the metal has the least influence, thus identifying a cheaper and easier method to prepare porpholactone M complex-based high pH-sensors. The influence of the pentafluorophenyl groups and the β-nitration were comparable with respect to their ability to increase the nucleophilicity of the porpholactone toward hydroxide, but the optical response for the pentafluorophenyl-substituted derivative were stronger. β-Nitration and pentafluorophenyl-substitution had additive effects.Keywords
This publication has 20 references indexed in Scilit:
- A two-step, one-pot route to swap the pyrroline moiety in meso-tetraaryldihydroxy-chlorins with an O/N-substituted oxazolineTetrahedron Letters, 2013
- meso-Arylporpholactones and their Reduction ProductsThe Journal of Organic Chemistry, 2012
- Tunable meso-Tetraphenyl-alkyloxazolo-chlorins and -bacteriochlorins†Oxazolochlorins 4. Oxazolochlorins 3: Khalil, G. E.; Daddario, P.; Lau, K. S. F.; Imtiaz, S.; King, M.; Gouterman, M.; Sidelev, A.; Ghandehari, M.; Brückner, C. Analyst2010, 135, 2125−2131.Organic Letters, 2011
- meso-Tetraarylporpholactones as high pH sensorsThe Analyst, 2010
- A ratiometric fluorescence sensor with broad dynamic range based on two pH-sensitive fluorophoresThe Analyst, 2005
- Use of Ag(II) as a removable template in porphyrin chemistry: diol cleavage products of [meso-tetraphenyl-2,3-cis-diolchlorinato]silver(II)Tetrahedron, 2003
- Synthesis and spectroscopic characterization of Ni, Zn, Pd and Pt tetra(pentafluorophenyl)porpholactone with comparisons to Mg, Zn, Y, Pd and Pt metal complexes of tetra(pentafluorophenyl)porphineJournal of Porphyrins and Phthalocyanines, 2002
- Optical pH Sensor of Electrostatically Immobilized Porphyrin on the Surface of Sulfonated-PolystyreneAnalytical Sciences, 1994
- Potentiometric and fiber optic sensors for pH based on an electropolymerized cobalt porphyrinAnalytical Chemistry, 1993
- Tetrakis(pentafluorophenyl)porpholactoneJournal of the American Chemical Society, 1989