Our Method of Povidone-Iodine Ointment and Gauze Dressings Reduced Catheter-Related Infection in Serious Cases
Authors:
- Atsushi FukunagaAFAtsushi Fukunaga
- Heiji NaritakaHNHeiji Naritaka
- Raita FukayaRFRaita Fukaya
- Masanao TabuseMTMasanao Tabuse
- Tsuneo NakamuraTNTsuneo Nakamura
- 1 February 2006
- journal article
- Published by S. Karger AG in Dermatology
- Vol. 212 (Suppl. 1) , 47-52
Abstract
In experiment 1, we evaluated our method of catheter care at subclavian vein insertion sites for the control of catheter-related infections in seriously ill neurosurgical patients who needed prolonged catheter placement, compared with an older method. In our method, the insertion site was prepared with 10% povidone-iodine solution, followed by application of 10% povidone-iodine ointment, and covered with sterile gauze and a transparent polyurethane dressing. The older method was based on 1996 guidelines for the prevention of intravascular device-related infections. Catheter colonization and mortality were both found to be significantly reduced with our method (p = 0.0214, p = 0.0379, respectively). In experiment 2, we evaluated whether a regimen of catheter care with 10% povidone-iodine ointment was more effective than that without povidone-iodine ointment for the prevention of infections. This suggested effectiveness of 10% povidone-iodine ointment for reduction of infection. Our method of catheter care was useful even in seriously ill neurosurgical patients.Keywords
This publication has 11 references indexed in Scilit:
- Characterization of skeletal phenotypes of TRα1PV and TRβPV mutant mice: implications for tissue thyroid status and T3 target gene expressionNuclear Receptor Signaling, 2006
- Povidone-Iodine Ointment and Gauze Dressings Associated With Reduced Catheter-Related Infection in Seriously Ill Neurosurgical PatientsInfection Control & Hospital Epidemiology, 2004
- Prevention of Intravascular Catheter–Related InfectionsAnnals of Internal Medicine, 2000
- Nosocomial Infections in a Neurosurgery Intensive Care UnitActa Neurochirurgica, 1999
- Mupirocin resistance in coagulase-negative staphylococci, after topical prophylaxis for the reduction of colonization of central venous cathetersJournal of Hospital Infection, 1995
- A prospective, randomized trial of gauze and two polyurethane dressings for site care of pulmonary artery catheters: Implications for catheter managementCritical Care Medicine, 1994
- Prevention of hemodialysis subclavian vein catheter infections by topical povidone-iodineKidney International, 1991
- Evaluation of Dressing Regimens for Prevention of Infection With Peripheral Intravenous CathetersJAMA, 1987
- Diagnosis of Central Venous Catheter-Related SepsisArchives of internal medicine (1960), 1987
- A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related InfectionThe New England journal of medicine, 1977