A comparison of DigiGait™ and TreadScan™ imaging systems: assessment of pain using gait analysis in murine monoarthritis
Authors:
Open Access
- 1 December 2013
- journal article
- research article
- Published by Taylor & Francis in Journal of Pain Research
- Vol. 7, 25-35
Abstract
Purpose: Carrageenan-induced arthritis is a painful acute arthritis model that is simple to induce, with peak pain and inflammation occurring at about 3 hours. This arthritis model can be evaluated using semiquantitative evoked or non-evoked pain scoring systems. These measures are subjective and are often time- and labor-intensive. It would be beneficial to utilize quantitative, nonsubjective evaluations of pain with rapid assessment tools. We sought to compare the DigiGait™ and TreadScan™ systems and to validate the two gait analysis platforms for detection of carrageenan-induced monoarthritis pain and analgesic response through changes in gait behavior. Methods: Non-arthritic mice and carrageenan-induced arthritic mice with and without analgesia were examined. A painful arthritic knee was produced by injection of 3% carrageenan into the knee joint of adult mice. Analgesic-treated mice were injected subcutaneously with 0.015 mg/mL (0.5 mg/kg) buprenorphine. Five-second videos were captured on the DigiGait™ or TreadScan™ system and, after calculating gait parameters, were compared using student's unpaired t-test. Results: We found the DigiGait™ system consistently measured significantly longer stride measures (swing time, stance time, and stride time) than did TreadScan™. Both systems' measures of variability were equal. Reproducibility was inconsistent on both systems. While both systems detected alterations in some gait measures after carrageenan injection, none of the alterations were seen with both systems. Only the TreadScan™ detected normalization of gait measures after analgesia, but the system could not detect normalization across all measures that altered due to arthritis pain. Time spent on analysis was dependent on operator experience. Conclusion: Neither the DigiGait™ nor TreadScan™ system was useful for measuring changes in pain behaviors or analgesic responses in acute inflammatory monoarthritic mice.Keywords
This publication has 23 references indexed in Scilit:
- Kinematic and dynamic gait compensations resulting from knee instability in a rat model of osteoarthritisArthritis Research & Therapy, 2012
- Abnormal gait, due to inflammation but not nerve injury, reflects enhanced nociception in preclinical pain modelsBrain Research, 2009
- Gait analysis in a murine model of collagen-induced arthritisArthritis Research & Therapy, 2007
- Emergence of Novel Color Vision in Mice Engineered to Express a Human Cone PhotopigmentScience, 2007
- Physical performance and soleus muscle fiber composition in wild-derived and laboratory inbred mouse strainsJournal of Applied Physiology, 2003
- Gait analysis as an objective measure in a chronic pain modelJournal of Neuroscience Methods, 2002
- Carrageenan-Induced Arthritis in the RatInflammation, 2000
- Gait Analysis in the MousePhysiology & Behavior, 1999
- Biomechanical gait alterations independent of speed in the healthy elderly: Evidence for specific limiting impairmentsArchives of Physical Medicine and Rehabilitation, 1998
- Gait alterations in dogs after transection of the anterior cruciate ligamentArthritis & Rheumatism, 1989