Hip, knee, and ankle kinematics of high range of motion activities of daily living
Authors:
Open Access
- 2 March 2006
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 24 (4) , 770-781
Abstract
Treatment of joint disease that results in limited flexion is often rejected by patients in non-Western cultures whose activities of daily living require a higher range of motion at the hip, knee, or ankle. However, limited information is available about the joint kinematics required for high range of motion activities, such as squatting, kneeling, and sitting cross-legged, making it difficult to design prosthetic implants that will meet the needs of these populations. Therefore, the objective of this work was to generate three-dimensional kinematics at the hip, knee, and ankle joints of Indian subjects while performing activities of daily living. Thirty healthy Indian subjects (average age: 48.2 ± 7.6 years) were asked to perform six trials of the following activities: squatting, kneeling, and sitting cross-legged. Floating axis angles were calculated at the joints using the kinematic data collected by an electromagnetic motion tracking device with receivers located on the subject's foot, shank, thigh, and sacrum. A mean maximum flexion of 157° ± 6° at the knee joint was required for squatting with heels up. Mean maximum hip flexion angles reached up to 95° ± 27° for squatting with heels flat. The high standard deviation associated with this activity underscored the large range in maximum hip flexion angles required by different subjects. Mean ankle range of flexion reached 58° ± 14° for the sitting cross-legged activity. The ranges of motion required to perform the activities studied are greater than that provided by most currently available joint prostheses, demonstrating the need for high range of motion implant design. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop ResKeywords
This publication has 32 references indexed in Scilit:
- Quantification of soft tissue artefact in motion analysis by combining 3D fluoroscopy and stereophotogrammetry: a study on two subjectsClinical Biomechanics, 2005
- Kinematics of the knee at high flexion angles: An in vitro investigationJournal of Orthopaedic Research, 2004
- Squatting Exercises in Older Adults: Kinematic and Kinetic ComparisonsMedicine & Science in Sports & Exercise, 2003
- Total ankle replacementThe Journal of Bone and Joint Surgery. British volume, 2003
- Mechanical loads at the knee joint during deep flexionJournal of Orthopaedic Research, 2002
- Knee joint kinematics in gait and other functional activities measured using flexible electrogoniometry: how much knee motion is sufficient for normal daily life?Gait & Posture, 2000
- Effect of skin movement on the analysis of skeletal knee joint motion during runningJournal of Biomechanics, 1997
- Surface movement errors in shank kinematics and knee kinetics during gaitGait & Posture, 1997
- Recovery of full flexion after total knee replacement in rheumatoid arthritis - a follow-up studyInternational Orthopaedics, 1997
- Effect of range of motion on the success of a total knee arthroplastyThe Journal of Arthroplasty, 1987