Method of standard additions for arsenic measurements in water by ICP sector field mass spectrometry at accuracy comparable to isotope dilution
Authors:
- 25 January 2010
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (5) , 624-630
Abstract
Mathematical model of the method of additions was reviewed to exclude the dilution and mass irreproducibility effects and assure the linear calibration. Selenium was identified as a high quality internal standard for arsenic measurements. At increased ratio measurement accuracy instrumental effects are important, and capabilities of the instrument must be carefully tested and accounted for. In measurements with double focusing electric and magnetic fields mass spectrometer Element 2 at medium mass resolution need for full integration of the peaks and role of the low frequency noise was evident. Averaging of the final results provided better accuracy of determination in comparison to the mean values of the intermediate data. If suitable internal standards can be selected, the method of standard additions is found to provide measurement accuracy comparable to that of isotope dilution. Comparison of the analytical signal of the test sample from direct measurements and the calibration graph is recommended as a test of the level of compensation for the possible matrix effects.Keywords
This publication has 47 references indexed in Scilit:
- Determination of As, Cd and Hg in emulsified vegetable oil by flow injection chemical vapour generation inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2008
- Scanning electrochemical microscopy coupled with intracellular standard addition method for quantification of enzyme activity in single intact cellsThe Analyst, 2007
- Underestimation of total arsenic concentration in groundwater samples determined by hydride generation quartz furnace atomic absorption spectrometry due to sample characteristicsAccreditation and Quality Assurance, 2007
- Use of handheld X-ray fluorescence spectrometry units for identification of arsenic in treated woodEnvironmental Pollution, 2007
- IMEP-12: trace elements in water; objective evaluation of the performance of the laboratories when measuring quality parameters prescribed in the European Directive 98/83/ECAccreditation and Quality Assurance, 2007
- The role of different soil sample digestion methods on trace elements analysis: a comparison of ICP-MS and INAA measurement resultsAccreditation and Quality Assurance, 2007
- Direct determination of arsenic in sea-water by reaction cell inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2007
- Direct analysis of clay and refractory materials slurries by inductively coupled plasma optical emission spectrometry with axial viewing using the simplified generalized standard additions methodJournal of Analytical Atomic Spectrometry, 2007
- Environmental risk assessment of heavy metal extractability in a biosludge from the biological wastewater treatment plant of a pulp and paper millEnvironmental Monitoring and Assessment, 2006
- International Measurement Evaluation Programme (IMEP); IMEP-14: Picturing the performance of analytical laboratories measuring trace elements in sedimentAccreditation and Quality Assurance, 2004