Efficacy of the RADPAD Protection Drape in Reducing Operators’ Radiation Exposure in the Catheterization Laboratory
- 1 November 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 10 (11)
Abstract
Background—: Interventional cardiologists are increasingly exposed to radiation-induced diseases like cataract and the stochastic risk of left-sided brain tumors. The RADPAD is a sterile, disposable, lead-free shield placed on the patient with the aim to minimize operator-received scatter radiation. The objective of the trial was to examine the RADPAD’s efficacy in a real-world situation. Methods and Results—: In the current, double-blind, sham-controlled, all-comer trial, patients undergoing diagnostic catheterization or percutaneous coronary interventions were randomized in a 1:1:1 ratio to a radiation absorbing shield (RADPAD), standard treatment (NOPAD), or a sham shield (SHAMPAD). The sham shield allowed testing for shield-induced radiation behavior. The primary outcome was the difference in relative exposure of the primary operator between the RADPAD and NOPAD arms and was defined as the ratio between operator’s exposure (E in µSv) and patient exposure (dose area product in mGy·cm 2 ), measured per procedure. A total of 766 consecutive coronary procedures were randomized to the use of RADPAD (N=255), NOPAD (N=255), or SHAMPAD (N=256). The use of RADPAD was associated with a 20% reduction in relative operator exposure compared with that of NOPAD ( P =0.01) and a 44% relative exposure reduction compared with the use of a SHAMPAD ( P P =0.009). Conclusions—: In clinical daily practice, the standard use of the RADPAD radiation shield reduced operator radiation exposure compared with procedures with NOPAD or SHAMPAD. This study supports the routine use of RADPAD in the catheterization laboratory. Clinical Trial Registration—: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03139968.Keywords
This publication has 22 references indexed in Scilit:
- Risk of cataract among interventional cardiologists and catheterization lab staff: A systematic review and meta‐analysisCatheterization and Cardiovascular Interventions, 2017
- Efficacy of RADPAD protective drape during coronary angiographyHerz, 2017
- Radiation Dose Reduction in Coronary CT AngiographyJACC: Cardiovascular Imaging, 2015
- Clinical and Procedural Characteristics Associated With Higher Radiation Exposure During Percutaneous Coronary Interventions and Coronary AngiographyCirculation: Cardiovascular Interventions, 2013
- Radiation Exposure During Percutaneous Coronary Interventions and Coronary Angiograms Performed by the Radial Compared With the Femoral RouteJACC: Cardiovascular Interventions, 2012
- Brain tumours among interventional cardiologists: a cause for alarm? Report of four new cases from two cities and a review of the literatureEuroIntervention, 2012
- The Radiation Issue in Cardiology: the time for action is nowCardiovascular Ultrasound, 2011
- Efficacy of the RADPAD Protective Drape During Real World Complex Percutaneous Coronary Intervention ProceduresThe American Journal of Cardiology, 2011
- Cancer risk from professional exposure in staff working in cardiac catheterization laboratory: Insights from the National Research Council's Biological Effects of Ionizing Radiation VII ReportAmerican Heart Journal, 2009
- Tumors of the Nervous System and Pituitary Gland Associated With Atomic Bomb Radiation ExposureJNCI: Journal of the National Cancer Institute, 2002