Rapid quantification of melamine in milk using competitive 1,1′-oxalyldiimidazole chemiluminescent enzyme immunoassay
Authors:
- 4 August 2010
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (9) , 2445-2450
Abstract
A novel competitive 1,1′-oxalyldiimidazole (ODI) chemiluminescent enzyme immunoassay (CLEIA) was developed as a method for rapid and simple screening of melamine in milk. Fat existing in milk acts as an inhibitor in the competitive binding interaction of melamine and anti-melamine in the presence of melamine-conjugated horseradish peroxidase. Thus, the calibration curve and sensitivity of competitive ODI CLEIA for the quantification of melamine in fat free milk were wider and better than those in milk containing fat. However, a centrifuge is not a good method for removing the inhibitor because a portion of the melamine is also removed with the fat. The incubation time (20 min) for the competitive binding interaction of anti-melamine and melamine in 20% milk diluted with PBS buffer of pH 7.4 was longer than that (10 min) in 100% milk even though the sensitivity of the former was better than latter. The limit of detection (1.12 ppb) determined in rapid ODI CLEIA (dynamic range: 3.8–125 ppb) for the quantification of melamine in 20% milk not containing fat was lower than those (6.3 and 9.0 ppb) calculated in relatively time-consuming luminol CLEIA and enzyme-linked immunosorbent assay (ELISA). Also, we expect that ODI-CLEIA (dynamic range: 62.5–2000 ppb) capable of directly quantifying melamine in 100% milk without any pretreatment can be applied as a new and simple method for rapid screening of melamine in milk.Keywords
This publication has 18 references indexed in Scilit:
- Residue analysis of melamine in milk products by micellar electrokinetic capillary chromatography with amperometric detectionFood Chemistry, 2010
- Hapten synthesis and antibody production for the development of a melamine immunoassayAnalytica Chimica Acta, 2010
- Electrochemical determination of melamine using oligonucleotides modified gold electrodesTalanta, 2009
- Rapid analysis of melamine in infant formula by sweeping-micellar electrokinetic chromatographyJournal of Chromatography A, 2009
- New spectrophotometric method for the quantitative determination of melamine using Mannich reactionJournal of Food Composition and Analysis, 2009
- Highly selective molecular recognition and high throughput detection of melamine based on molecularly imprinted sol–gel filmAnalytica Chimica Acta, 2009
- Determination of melamine in animal feed based on liquid chromatography tandem mass spectrometry analysis and dynamic microwave-assisted extraction coupled on-line with strong cation-exchange resin clean-upAnalytical and Bioanalytical Chemistry, 2009
- Melamine contaminationAnalytical and Bioanalytical Chemistry, 2009
- Subpicogram Determination of Melamine in Milk Products Using a Luminol−Myoglobin Chemiluminescence SystemJournal of Agricultural and Food Chemistry, 2009
- Detection of Melamine Using Commercial Enzyme-Linked Immunosorbent Assay TechnologyJournal of Food Protection, 2008