Interocular biometric parameters comparison measured with swept-source technology
Authors:
Open Access
- 21 August 2021
- journal article
- research article
- Published by Springer Nature in International Ophthalmology
- Vol. 42 (1) , 239-251
Abstract
Purpose: In the event that any ocular parameter involved in the calculation of intraocular lens power could not be properly measured in one eye, it is important to know whether clinically relevant differences between both eyes can be expected. The aim of this work is to evaluate the symmetry of interocular biometric parameters. Methods: This was a prospective, cross-sectional study involving 4090 subjects. Patients underwent consecutive swept-source optical biometry performed with an IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany). The biometric parameters that were evaluated were: axial length (AL), mean anterior curvature (Rm), anterior chamber depth (ACD), crystalline lens thickness (LT), central corneal thickness (CCT) and white-to-white (WTW). The Chang–Waring chord distance (CWC-D) and the Chang–Waring chord angle (CWC-A) were also evaluated. Results: There is an excellent correlation between both eyes for almost all the biometric parameters under study, with the exception of the CWC. Agreement for AL was better for eyes shorter than 24 mm. The linearity of the OD-vs-OS relationship can be correctly assumed for all parameters (Cusum test: p > 0.05 in all cases). Conclusion: There are no clinically significant interocular differences for the biometric parameters under study, although for all of them, except the LT, statistically significant differences did arise. In the case of AL, moderate differences can be expected in eyes larger than 24 mm.Keywords
Funding Information
- Universidad Complutense de Madrid
This publication has 32 references indexed in Scilit:
- An Evaluation of the IOLMaster 700Eye & Contact Lens: Science & Clinical Practice, 2019
- Influence of corneal power on intraocular lens power of the second eye in the SRK/T formula in bilateral cataract surgeryBMC Ophthalmology, 2017
- The Subject-Fixated Coaxially Sighted Corneal Light Reflex: A Clinical Marker for Centration of Refractive Treatments and DevicesAmerican Journal of Ophthalmology, 2014
- Evaluation of myopic corneal diameter with the Orbscan II Topography SystemGraefe's Archive for Clinical and Experimental Ophthalmology, 2012
- First Eye Prediction Error Improves Second Eye Refractive OutcomeOphthalmology, 2011
- Intraocular Lens Power Selection in the Second Eye of Patients Undergoing Bilateral, Sequential Cataract ExtractionOphthalmology, 2010
- Intraocular lens power in bilateral cataract surgery: Whether adjusting for error of predicted refraction in the first eye improves prediction in the second eyeJournal of Cataract & Refractive Surgery, 2006
- High Interocular Corneal Symmetry in Average Simulated Keratometry, Central Corneal Thickness, and Posterior ElevationOptometry and Vision Science, 2005
- Optical aberrations of the human anterior corneaJournal of Cataract & Refractive Surgery, 2003
- Comparing predictability between eyes after bilateral laser in situ keratomileusisOphthalmology, 1999