Abstract
Object: A cortical bone trajectory (CBT) is a new pedicle screw trajectory that maximizes the thread contact with cortical bone surface, providing enhanced screw purchase. Despite the increased use of the CBT in the lumbar spine, little is known about the insertion technique for the sacral CBT. The aim of this study was to introduce a novel sacral pedicle screw trajectory. This trajectory engages with denser bone maximally by the screw penetrating the S-1 superior endplate through a more medial entry point than the traditional technique, and also has safety advantages, with the protrusion of the screw tip into the intervertebral disc space carrying no risk of neurovascular injury. Methods: In this study, the CT scans of 50 adults were studied for morphometric measurement of the new trajectory. The entry point was supposed to be the junction of the center of the superior articular process of S-1 and approximately 3 mm inferior to the most inferior border of the inferior articular process of L-5. The direction was straight forward in the axial plane without convergence, angulated cranially in the sagittal plane penetrating the middle of the sacral endplate. The cephalad angle to the sacral endplate, length of trajectory, and safety of the trajectory were investigated. Next, the insertional torque of pedicle screws using this technique was measured intraoperatively in 19 patients and compared with the traditional technique. Results: The mean cephalad angle in these 50 patients was 30.7° ± 5.1°, and the mean length of trajectory was 31.5 ± 3.5 mm. The CT analysis revealed that the penetrating S-1 endplate technique did not cause any neurovascular injury anteriorly in any case. The new technique demonstrated an average of 141% higher insertional torque than the traditional monocortical technique. Conclusions: The penetrating S-1 endplate technique through the medial entry point is suitable for the connection of lumbar CBT, has revealed favorable stability for lumbosacral fixation, and has reduced the potential risk of neurovascular injuries.Keywords
This publication has 29 references indexed in Scilit:
- Advantages of the Paraspinal Muscle Splitting Approach in Comparison With Conventional Midline Approach for S1 Pedicle Screw PlacementSpine, 2010
- Neurovascular risks of sacral screws with bicortical purchase: an anatomical studyEuropean Spine Journal, 2007
- A Stronger Bicortical Sacral Pedicle Screw Fixation Through The S1 EndplateSpine, 2005
- The Effects of Cyclic Loading on Pull-Out Strength of Sacral Screw FixationSpine, 2000
- Can Insertional Torque Predict Screw Loosening and Related Failures?Spine, 2000
- Morphometric Evaluation of the First Sacral Vertebra and the Projection of Its Pedicle on the Posterior Aspect of the SacrumSpine, 1995
- Sacral Screw Loads in Lumbosacral Fixation for Spinal DeformitySpine, 1993
- Surgical Anatomy of the SacrumSpine, 1991
- Solitary Spinal PlasmacytomasJournal of Spinal Disorders, 1988
- Depth of Insertion of Transpedicular Vertebral Screws into Human VertebraeJournal of Spinal Disorders, 1988