Friction factors in pulsed turbulent flow
Authors:
- 1 April 1971
- journal article
- research article
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 49 (2) , 220-223
Abstract
An apparatus for investigating pulsed turbulent liquid flow in a 2 in. diameter, 80 ft. pipeline is described. The pulsation unit was powered by compressed air with a consumption of up to 2.7 std. cu.ft./min. at 35 lb/in2 gauge. The pressure drop for water flowing at mean velocities of 7.66 to 12.28 ft./sec. has been measured, both for steady flow and for pulsed flow, at frequencies between 0.48 and 0.82 Hz. The experimentally measured pressure versus time curves for pulsed flow can be matched fairly closely by a solution of Euler's equation employing the friction factors measured under steady flow conditions.Keywords