Long‐Term Survival of Mitroflow and Perimount Aortic Valve Replacements
Authors:
- Lytfi KrasniqiLKLytfi Krasniqi
- Jordi Sanchez DahlJDJordi Sanchez Dahl
- Christian Greve JensenCJChristian Greve Jensen
- Poul Erik MortensenPMPoul Erik Mortensen
- Axel BrandesAxel Brandes
- Oke GerkeOke Gerke
- Emil Johannes RavnEREmil Johannes Ravn
- Viktor PoulsenVPViktor Poulsen
- Lars Peter Schødt RiberLRLars Peter Schødt Riber
Open Access
- 1 January 2024
- journal article
- research article
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 2024 (1)
Abstract
Objectives: The American College of Cardiology (ACC) guidelines recommend the same imaging frequency for all bioprosthetic valves, but some have demonstrated poor durability. We aimed to assess mortality differences between small (19–21 mm) and large (23–29 mm) in Mitroflow and Carpentier‐Edwards Perimount aortic valves.Methods: A retrospective observational study was conducted by all patients undergoing isolated surgical aortic valve replacement with Mitroflow or Perimount in Western Denmark between 1999 and 2014 and followed until January 2024. The primary endpoint was all‐cause mortality. Secondary endpoints were cardiovascular mortality and sudden cardiac death. A propensity score‐matched analysis was performed.Results: A total of 1150 patients were analyzed, with 496 (43%) receiving Mitroflow valves and 654 (57%) receiving Perimount valves. In the Mitroflow group, 108 (22%) had a valve size of 19–21 mm, and 388 (78%) in the size range of 23–29 mm. In the Perimount group, the distribution was 99 (15%) and 555 (85%), respectively. The compromised survival of Mitroflow valves was attributed to the valve type, regardless of the valve sizes. Larger Mitroflow valves exhibited the same compromised late mortality as smaller valves, 66.7% vs 61.5%, respectively (p = 0.95). The same pattern of mortality was observed in the matched population, with Perimount demonstrating significant lower risk of mortality.Conclusion: Mitroflow valves were associated with a poorer prognosis compared to Perimount valves. Additionally, larger Mitroflow valves were not associated with an improved prognosis compared to smaller valve sizes. EuroSCORE2 had a significant impact on patient survival.Keywords
This publication has 28 references indexed in Scilit:
- Hemodynamic Comparison between the Avalus and the Perimount Magna Ease Aortic Bioprosthesis up to 5 YearsThe Thoracic and Cardiovascular Surgeon, 2022
- Comparison of Long-term Performance of Bioprosthetic Aortic Valves in Sweden From 2003 to 2018JAMA Network Open, 2022
- Harmonization of the definition of sudden cardiac death in longitudinal cohorts of the European Sudden Cardiac Arrest network – towards Prevention, Education, and New Effective Treatments (ESCAPE-NET) consortiumAmerican Heart Journal, 2022
- Structural valve degeneration of bioprosthetic aortic valves: A network meta-analysisThe Journal of Thoracic and Cardiovascular Surgery, 2022
- Valve Academic Research Consortium 3: Updated Endpoint Definitions for Aortic Valve Clinical ResearchJACC, 2021
- Characteristics of surgical prosthetic heart valves and problems around labeling: A document from the European Association for Cardio-Thoracic Surgery (EACTS)—The Society of Thoracic Surgeons (STS)—American Association for Thoracic Surgery (AATS) Valve Labelling Task ForceThe Journal of Thoracic and Cardiovascular Surgery, 2019
- The fate of small-size pericardial heart valve prostheses in an older patient populationThe Journal of Thoracic and Cardiovascular Surgery, 2017
- The Danish Civil Registration System as a tool in epidemiologyEuropean Journal of Epidemiology, 2014
- The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studiesThe Lancet, 2007
- Aortic stenosis∗The American Journal of Cardiology, 1958