Effect of internal and external conditions on ionization processes in the FAPA ambient desorption/ionization source
- 2 September 2014
- journal article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (29) , 7511-7521
Abstract
Ambient desorption/ionization (ADI) sources coupled to mass spectrometry (MS) offer outstanding analytical features: direct analysis of real samples without sample pretreatment, combined with the selectivity and sensitivity of MS. Since ADI sources typically work in the open atmosphere, ambient conditions can affect the desorption and ionization processes. Here, the effects of internal source parameters and ambient humidity on the ionization processes of the flowing atmospheric pressure afterglow (FAPA) source are investigated. The interaction of reagent ions with a range of analytes is studied in terms of sensitivity and based upon the processes that occur in the ionization reactions. The results show that internal parameters which lead to higher gas temperatures afforded higher sensitivities, although fragmentation is also affected. In the case of humidity, only extremely dry conditions led to higher sensitivities, while fragmentation remained unaffected.Keywords
This publication has 41 references indexed in Scilit:
- Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/IonizationChemical Reviews, 2013
- Infrared Laser Ablation Atmospheric Pressure Photoionization Mass SpectrometryAnalytical Chemistry, 2012
- Ambient mass spectrometry: Approaching the chemical analysis of things as they areJournal of Analytical Atomic Spectrometry, 2011
- Atmospheric pressure-thermal desorption (AP-TD)/electrospray ionization-mass spectrometry for the rapid analysis of Bacillus sporesThe Analyst, 2010
- Beta electron-assisted direct chemical ionization (BADCI) probe for ambient mass spectrometryChemical Communications, 2009
- Electrospray‐assisted laser desorption/ionization mass spectrometry for direct ambient analysis of solidsRapid Communications in Mass Spectrometry, 2005
- Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient ConditionsAnalytical Chemistry, 2005
- Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray IonizationScience, 2004
- The viscosity and thermal conductivity of pure monatomic gases from their normal boiling point up to 5000 K in the limit of zero density and at 0.101325 MPaJournal of Physical and Chemical Reference Data, 1990
- Thermal Conductivity of Nine Polyatomic Gases at Low DensityJournal of Physical and Chemical Reference Data, 1990