Quantitative Detection ofLegionella pneumophilain Water Samples by Immunomagnetic Purification and Real-Time PCR Amplification of thedotAGene
Authors:
Open Access
- 1 July 2005
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 71 (7) , 3433-3441
Abstract
A new real-time PCR assay was developed and validated in combination with an immunomagnetic separation system for the quantitative determination ofLegionella pneumophilain water samples. Primers that amplify simultaneously an 80-bp fragment of thedotAgene fromL. pneumophilaand a recombinant fragment including a specific sequence of thegyrBgene fromAeromonas hydrophila, added as an internal positive control, were used. The specificity, limit of detection, limit of quantification, repetitivity, reproducibility, and accuracy of the method were calculated, and the values obtained confirmed the applicability of the method for the quantitative detection ofL. pneumophila. Moreover, the efficiency of immunomagnetic separation in the recovery ofL. pneumophilafrom different kinds of water was evaluated. The recovery rates decreased as the water contamination increased (ranging from 59.9% for distilled water to 36% for cooling tower water), and the reproducibility also decreased in parallel to water complexity. The feasibility of the method was evaluated by cell culture and real-time PCR analysis of 60 samples in parallel. All the samples found to be positive by cell culture were also positive by real-time PCR, while only eight samples were found to be positive only by PCR. Finally, the correlation of both methods showed that the number of cells calculated by PCR was 20-fold higher than the culture values. In conclusion, the real-time PCR method combined with immunomagnetic separation provides a sensitive, specific, and accurate method for the rapid quantification ofL. pneumophilain water samples. However, the recovery efficiency of immunomagnetic separation should be considered in complex samples.Keywords
This publication has 43 references indexed in Scilit:
- Quantification of Intestinal Bacterial Populations by Real-Time PCR with a Universal Primer Set and Minor Groove Binder Probes: a Global Approach to the Enteric FloraJournal of Clinical Microbiology, 2004
- Quantitative Detection of Listeria monocytogenes and Listeria innocua by Real-Time PCR: Assessment of hly , iap , and lin02483 Targets and AmpliFluor TechnologyApplied and Environmental Microbiology, 2004
- Development and Clinical Evaluation of an Internally Controlled, Single-Tube Multiplex Real-Time PCR Assay for Detection of Legionella pneumophila and Other Legionella SpeciesJournal of Clinical Microbiology, 2003
- Quantification of Bacteria Adherent to Gastrointestinal Mucosa by Real-Time PCRJournal of Clinical Microbiology, 2002
- Real-Time Quantitative PCR for Detection ofHelicobacter pyloriJournal of Clinical Microbiology, 2002
- Detection of Legionellae in Hospital Water Samples by Quantitative Real-Time LightCycler PCRApplied and Environmental Microbiology, 2001
- Development of Conventional and Real-Time PCR Assays for Detection of Legionella DNA in Respiratory SpecimensJournal of Clinical Microbiology, 2001
- Direct Detection of Legionella Species from Bronchoalveolar Lavage and Open Lung Biopsy Specimens: Comparison of LightCycler PCR, In Situ Hybridization, Direct Fluorescence Antigen Detection, and CultureJournal of Clinical Microbiology, 2001
- Detection ofLegionella pneumophilain bioaerosols by polymerase chain reactionCanadian Journal of Microbiology, 2001
- Genome analysis of Legionella ssp. by orthogonal field alternation gel electrophoresis (OFAGE)FEMS Microbiology Letters, 1990