Aerosol delivery in models of pediatric high flow nasal oxygen and mechanical ventilation
Open Access
- 12 December 2022
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 58 (3) , 878-886
Abstract
Background: Aerosol drug delivery during high flow nasal oxygen (HFNO) and invasive mechanical ventilation (IMV) are key respiratory care strategies available for the treatment of pediatric patients. We aimed to quantify the impact of different HFNO and IMV set‐ups on tracheal drug delivery via a vibrating mesh nebuliser (VMN).Methods: Percent tracheal dose via VMN was quantified during HFNO therapy and IMV in a benchtop model of a 9‐month‐old infant. Under HFNO, 3 cannula sizes were used at 3 flow rate settings with the VMN placed at the dry side of the humidifier. Under IMV, tracheal dose when VMN was placed at the dry side of the humidifier, 15 cm from the wye and between the wye and endotracheal tube (ETT) was assessed. Salbutamol at 2.5 mg/2.5 ml (1 mg/ml) was used for each test (N = 5). The impact of VMN refill on circuit pressure under HFNO and IMV was also assessed.Results: Tracheal dose was highest during HFNO with the largest cannula size (OPT318) set to the lowest flow rate setting of 2 L/min (liter per minute) (5.80 ± 0.17%). Increasing flow rate reduced tracheal drug delivery for all cannulas. For IMV, VMN on the dry side of the humidifier and between the wye and ETT gave optimal drug delivery (4.49 ± 0.14% vs. 4.43 ± 0.26% respectively). VMN refill did not impact circuit pressure for either HFNO therapy or IMV.Conclusions: Gas flow rate and cannula size during HFNO and VMN position during IMV has a significant effect on tracheal drug delivery in a pediatric setting.Keywords
This publication has 37 references indexed in Scilit:
- Albuterol Delivery by 4 Different Nebulizers Placed in 4 Different Positions in a Pediatric Ventilator In Vitro ModelRespiratory Care, 2013
- Influences of Cannula Size and Flow Rate on Aerosol Drug Delivery Through the Vapotherm Humidified High-Flow Nasal Cannula SystemPediatric Critical Care Medicine, 2013
- Influence of Jet Nebulization and Oxygen Delivery on the Fraction of Inspired Oxygen: An Experimental ModelJournal of Aerosol Medicine and Pulmonary Drug Delivery, 2009
- Aerosol Delivery through Nasal Cannulas: An In Vitro StudyJournal of Aerosol Medicine and Pulmonary Drug Delivery, 2008
- A Prospective Controlled Trial of Albuterol Aerosol Delivered Via Metered Dose Inhaler-Spacer Device (MDI) Versus Jet Nebulizer in Ventilated Preterm NeonatesAmerican Journal of Perinatology, 2001
- The Sophia Anatomical Infant Nose-Throat (Saint) Model: A Valuable Tool to Study Aerosol Deposition in InfantsJournal of Aerosol Medicine, 2001
- Delivery of salbutamol to nonventilated preterm infants by metered-dose inhaler, jet nebulizer, and ultrasonic nebulizerEuropean Respiratory Journal, 1998
- Efficacy of Bronchodilator Therapy in BronchiolitisArchives of Pediatrics & Adolescent Medicine, 1996
- The influence of age on aerosol deposition in children with cystic fibrosisEuropean Respiratory Journal, 1994
- Respiratory response to salbutamol (albuterol) in ventilator-dependent infants with chronic lung disease: pressurized aerosol delivery versus intravenous injectionIntensive Care Medicine, 1993