Indirect Ion Selective Electrode Methods Potentially Overestimate Peritoneal Dialysate Sodium Losses
- 10 November 2013
- journal article
- research article
- Published by Wiley in Therapeutic Apheresis and Dialysis
- Vol. 18 (4) , 321-325
Abstract
Measurements of dialysate sodium are used to estimate peritoneal dialysis sodium losses and sodium sieving, a measure of hydraulic permeability of the peritoneum. Peritoneal dialysates differ from serum samples in terms of pH, osmolality, protein and glucose concentration. We wished to determine whether these factors affected sodium measurement. Dialysate samples were taken from 52 consecutive peritoneal dialysis patients attending for a standard peritoneal dialysis equilibrium test (PET), 20 with standard lactate dialysate and 32 with neutral pH dialysate and sodium was measured by both flame photometry and indirect ion selective electrode (ISE). Sodium measured by ISE consistently overestimated that measured by flame photometer, mean bias 1.5 mmol/L (95% confidence limits 1.2 to 1.8), P < 0.001. Sodium was lower in fresh neutral pH dialysates by both methods – flame 125.3 ± 1.17 vs. 131.6 ± 0.39 mmol/L, than standard lactate dialysates ISE 127.4 ± 1.05 vs 132.7 ± 0.27 mmol/L, P < 0.001. Glucose was higher in fresh neutral pH dialysates 122.7 ± 1.1 vs. standard lactate dialysates 116.7 ± 0.4 mmol/L, P < 0.001. On multiple regression analysis, only glucose was found to be an independent factor for sodium measurement, F = 14.78, β = −0.0851, SEM 0.022, 95% confidence limits −1.28 to −0.042. In this study there was a small but consistent difference between sodium measurements by ISE and flame photometry during the PET. Sodium measurements by either method appeared to be affected by hypertonic dialysates, but there were differences with pH. This may potentially lead to errors in both overestimating peritoneal sodium losses and the proportion of patients with ultrafiltration failure due to loss of sodium sieving.Keywords
This publication has 15 references indexed in Scilit:
- Extracellular Volume Expansion in Peritoneal Dialysis PatientsThe International Journal of Artificial Organs, 2012
- NT-proBNP, fluid volume overload and dialysis modality are independent predictors of mortality in ESRD patientsNephrology Dialysis Transplantation, 2009
- Categorization of sodium sieving by 2.27% and 3.86% peritoneal equilibration tests--a comparative analysis in the clinical settingNephrology Dialysis Transplantation, 2009
- Sodium removal and sodium concentration during peritoneal dialysis: effects of three methods of sodium measurementNephrology Dialysis Transplantation, 2004
- Effect of fluid and sodium removal on mortality in peritoneal dialysis patientsKidney International, 2001
- Peritoneal Sodium Mass Removal in Continuous Ambulatory Peritoneal Dialysis and Automated Peritoneal Dialysis: Influence on Blood Pressure ControlAmerican Journal of Nephrology, 2001
- Recommendations for Measurement of and Conventions for Reporting Sodium and Potassium by Ion-Selective Electrodes in Undiluted Serum, Plasma or Whole BloodClinical Chemistry and Laboratory Medicine (CCLM), 2000
- Hyponatremia: evaluating the correction factor for hyperglycemiaThe American Journal of Medicine, 1999
- A Comparison of the Measurement of Sodium and Potassium by Flame Photometry and Ion-Selective ElectrodeAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1985
- Hyperglycemia-Induced Hyponatremia — Calculation of Expected Serum Sodium DepressionNew England Journal of Medicine, 1973