Thin Layer Ionophore-Based Membrane for Multianalyte Ion Activity Detection
- 10 July 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (15) , 7729-7737
Abstract
A concept is introduced that allows one to detect the activity of multiple ions simultaneously and selectively with a single ion-selective membrane. This is demonstrated with ∼300 nm thin plasticized PVC membranes containing up to two ionophores in addition to a lipophilic cation-exchanger, overlaid on an electropolymerized poly-3-octylthiophene (POT) film as the electron to ion transducer. The ion-selective membranes are formulated under ionophore depleted conditions (avoiding excess of ionophore over ion-exchanger), which is purposely different from common practice with ion-selective electrodes. Cyclic voltammetry is used to interrogate the films. An anodic scan partially oxidizes the POT underlayer, which results in the expulsion of cations from the membrane at an appropriate potential. During the scan of a membrane containing multiple ionophores, the least bound ion is expelled first, giving distinct Gaussian peak shaped ion transfer voltammetric waves that are analyzed in terms of their peak potential. These potentials are found to change with the logarithm of the ion activity, in complete analogy to ion-selective electrodes, and multiple such waves are observed with multiple ionophores that exhibit no obvious interference from the other ionophores present in the membrane. The concept is established with lithium and calcium ionophores and accompanied by a response model that assumes complete equilibration of the membrane at every applied potential. On the basis of the model, diffusion coefficients in the membrane or aqueous phase bear no influence on the peak potentials as long as thin layer behavior is observed, further confirming the analogy to a potentiometric experiment. Idealized ion transfer waves are narrower than experimental findings, which is explained by a broader than expected anodic peak for the oxidation of conducting polymer. The correspondence between experiment and theory is otherwise excellent in terms of thin layer behavior and Nernstian shift of the peaks with analyte concentration.Keywords
Funding Information
- Seventh Framework Programme (614002)
- Schweizerische Nationalfonds zur F?rderung der Wissenschaftlichen Forschung
This publication has 32 references indexed in Scilit:
- Evidence for a Surface Confined Ion-to-Electron Transduction Reaction in Solid-Contact Ion-Selective Electrodes Based on Poly(3-octylthiophene)Analytical Chemistry, 2013
- All‐Solid‐State Ion Selective and All‐Solid‐State Reference ElectrodesElectroanalysis, 2012
- Nanostructured materials in potentiometryAnalytical and Bioanalytical Chemistry, 2010
- Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodesJournal of Solid State Electrochemistry, 2008
- Potentiometric Ion SensorsChemical Reviews, 2008
- Solution-cast films of poly(3,4-ethylenedioxythiophene) as ion-to-electron transducers in all-solid-state ion-selective electrodesSensors and Actuators B: Chemical, 2004
- Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron TransducersAnalytical Chemistry, 1999
- Electron transfer at conducting polymer film electrodes: mechanism and kinetics of ferrocene oxidation at poly(3-octylthiophene)Journal of Electroanalytical Chemistry, 1997
- All solid-state poly(vinyl chloride) membrane ion-selective electrodes with poly(3-octylthiophene) solid internal contactThe Analyst, 1994
- Electrochemical study of poly(3-octylthiophene) film electrodes II. Reversible redox/conductivity state switching. Impedance studySynthetic Metals, 1991