Evaluating the Final Color of Restorations with Three CAD/CAM Core Materials (Co–Cr, Zirconia, and PEEK), Veneered by Two Methods (Indirect CAD/CAM Composite and Heat-Pressed Ceramics)
Open Access
- 27 July 2023
- journal article
- research article
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-8
Abstract
Background. This study aimed to evaluate the final color of restorations with three different core materials (Co–Cr, Zirconia, and PEEK) veneered with heat-pressed ceramic or CAD/CAM composite. Methods. Forty cores in the form of square with dimensions of 10 × 10 mm and thickness of 0.5 mm were milled from Zirconia and Co–Cr blocks and were veneered with either A2 shade CAD/CAM composite resin or heat-press ceramic (n = 10). Ten samples from polyetheretherketone blocks were only veneered with composite resins. A2 shade veneer material with 2 mm served as control for color evaluation of samples. Color parameters were measured by spectrophotometer. The data were analyzed using one-way ANOVA and Tukey’s post hoc test. Results. The mean color differences between Co–Cr, Zirconia and PEEK samples veneered with composite and the control sample were 2.91 (±0.45), 3.24 (±0.33), and 2.75 (±0.35) and for Co–Cr and Zirconia in ceramic groups were 6.46 (±0.32) and 1.97 (±0.19), respectively. One-way ANOVA and Tukey’s post hoc test showed a significant difference between the core groups veneered with ceramic ( ). The type of core material in the composite veneered samples, however, did not make a significant difference ( ). All groups except for Co–Cr-ceramic showed clinically acceptable results (ΔE < 3.7). Conclusion. Type of core material presented significant effect on the final color of restorations when ceramic was used as a veneer material. Conversely, the final color of composite veneer restorations is not affected by the core type. CAD/CAM composites can provide adequate color coverage for different core materials without exceeding a minimum clinically acceptable thickness.Keywords
All Related Versions
Funding Information
- Dental Research Center, Tehran University of Medical Sciences (99-3-234-49155)
This publication has 20 references indexed in Scilit:
- Spectrophotometric Evaluation of Polyetheretherketone (PEEK) as a Core Material and a Comparison with Gold Standard Core MaterialsMaterials, 2016
- The effect of various sandblasting conditions on surface changes of dental zirconia and shear bond strength between zirconia core and indirect composite resinThe Journal of Advanced Prosthodontics, 2015
- Effect of metal primers and tarnish treatment on bonding between dental alloys and veneer resinThe Journal of Advanced Prosthodontics, 2015
- Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crownsThe Journal of Advanced Prosthodontics, 2013
- Effect of abutment tooth color, cement color, and ceramic thickness on the resulting optical color of a CAD/CAM glass-ceramic lithium disilicate-reinforced crownThe Journal of Prosthetic Dentistry, 2011
- Layered color of all-ceramic core and veneer ceramicsThe Journal of Prosthetic Dentistry, 2007
- Influence of Abutment Materials on the Resultant Color of Heat-pressed Lithium Disilicate CeramicsDental Materials Journal, 2006
- Spectrophotometric evaluation of the optical influence of different metal alloys and porcelains in the metal-ceramic complexThe Journal of Prosthetic Dentistry, 2004
- Colorimetric Evaluation of the Influence of Five Different Restorative Materials on the Color of Veneered Densely Sintered AluminaJournal of Esthetic and Restorative Dentistry, 2003
- Fracture strength of all-porcelain, resinbonded bridges after testing in an artificial oral environmentJournal of Dentistry, 1993