Comparison of 4D Phase-Contrast MRI Flow Measurements to Computational Fluid Dynamics Simulations of Cerebrospinal Fluid Motion in the Cervical Spine
Open Access
- 21 December 2012
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (12) , e52284
Abstract
Cerebrospinal fluid (CSF) dynamics in the cervical spinal subarachnoid space (SSS) have been thought to be important to help diagnose and assess craniospinal disorders such as Chiari I malformation (CM). In this study we obtained time-resolved three directional velocity encoded phase-contrast MRI (4D PC MRI) in three healthy volunteers and four CM patients and compared the 4D PC MRI measurements to subject-specific 3D computational fluid dynamics (CFD) simulations. The CFD simulations considered the geometry to be rigid-walled and did not include small anatomical structures such as nerve roots, denticulate ligaments and arachnoid trabeculae. Results were compared at nine axial planes along the cervical SSS in terms of peak CSF velocities in both the cranial and caudal direction and visual interpretation of thru-plane velocity profiles. 4D PC MRI peak CSF velocities were consistently greater than the CFD peak velocities and these differences were more pronounced in CM patients than in healthy subjects. In the upper cervical SSS of CM patients the 4D PC MRI quantified stronger fluid jets than the CFD. Visual interpretation of the 4D PC MRI thru-plane velocity profiles showed greater pulsatile movement of CSF in the anterior SSS in comparison to the posterior and reduction in local CSF velocities near nerve roots. CFD velocity profiles were relatively uniform around the spinal cord for all subjects. This study represents the first comparison of 4D PC MRI measurements to CFD of CSF flow in the cervical SSS. The results highlight the utility of 4D PC MRI for evaluation of complex CSF dynamics and the need for improvement of CFD methodology. Future studies are needed to investigate whether integration of fine anatomical structures and gross motion of the brain and/or spinal cord into the computational model will lead to a better agreement between the two techniques.Keywords
This publication has 50 references indexed in Scilit:
- Age-Specific Characteristics and Coupling of Cerebral Arterial Inflow and Cerebrospinal Fluid DynamicsPLOS ONE, 2012
- A One-Dimensional Model of the Spinal Cerebrospinal-Fluid CompartmentJournal of Biomechanical Engineering, 2012
- Spinal Subarachnoid Space Pressure Measurements in an In Vitro Spinal Stenosis Model: Implications on Syringomyelia TheoriesJournal of Biomechanical Engineering, 2010
- Peak CSF Velocities in Patients with Symptomatic and Asymptomatic Chiari I MalformationAmerican Journal of Neuroradiology, 2010
- Cerebrospinal fluid dynamics in the human cranial subarachnoid space: an overlooked mediator of cerebral disease. I. Computational modelJournal of The Royal Society Interface, 2010
- Improved SNR in phase contrast velocimetry with five‐point balanced flow encodingMagnetic Resonance in Medicine, 2010
- The influence of coughing on cerebrospinal fluid pressure in an in vitro syringomyelia model with spinal subarachnoid space stenosisFluids and Barriers of the CNS, 2009
- Three-Dimensional Computational Modeling of Subject-Specific Cerebrospinal Fluid Flow in the Subarachnoid SpaceJournal of Biomechanical Engineering, 2008
- Computational investigation of subject-specific cerebrospinal fluid flow in the third ventricle and aqueduct of SylviusJournal of Biomechanics, 2007
- Foramen magnum cerebrospinal fluid flow characteristics in children with Chiari I malformation before and after craniocervical decompressionJournal of neurosurgery. Pediatrics, 2004