Long‐term Clinical Results using the Artificial Urinary Sphincter around Bowel
Author:
- 1 July 1989
- journal article
- research article
- Published by Wiley in British Journal of Urology
- Vol. 64 (1) , 56-60
Abstract
Summary— Four patients are presented in whom bowel was used to reconstruct a bladder. As a sphincteric mechanism was absent in all 4, the cuff from the artificial urinary sphincter was placed around the bowel to provide continence. This allowed for “normal” urination. The longest follow‐up period was 11 years and the shortest 1.5 years. Both clinical and experimental data show that bowel will tolerate compression from the artificial urinary sphincter provided infection does not supervene and the pressure does not exceed 80 cm of waterKeywords
This publication has 7 references indexed in Scilit:
- Le Bag: Total Replacement of the Bladder Using an Ileocolonic PouchJournal of Urology, 1986
- Bladder replacement by ileocystoplasty following radical cystectomyWorld Journal of Urology, 1985
- Enteroplasty to Ablate Bowel Contractions in the Reconstructed Bladder: A Case ReportJournal of Urology, 1985
- The Use of the AMS-AS800 Artificial Sphincter for Continent Urinary Diversion. I. Investigations, Including Pressure-Flow Studies, Using Rabbit Intestinal LoopsJournal of Urology, 1985
- Evaluation of AMS 800 artificial sphincter for continent urinary diversion using intestinal loopsUrology, 1985
- Reconstruction of the Lower Urinary Tract: Observations on Bowel Dynamics and the Artificial Urinary SphincterJournal of Urology, 1985
- Total Reconstruction of the Lower Urinary Tract Using Bowel and the Artificial Urinary SphincterJournal of Urology, 1984