Impact of membrane oxygenators on pulsatile versus nonpulsatile perfusion in a neonatal model
Authors:
- 1 March 2000
- journal article
- research article
- Published by SAGE Publications in Perfusion
- Vol. 15 (2) , 111-120
Abstract
We investigated the effects of two new hollow-fiber membrane oxygenators, the Capiox SX10 and the Lilliput 901, on pulsatile versus nonpulsatile perfusion in an in vitro model designed to simulate a 3 kg infant. The experiments were divided into eight groups (six pulsatile and two nonpulsatile), according to the equipment and settings used. Each group included six tests. In all experiments, the pseudo-patient’s mean arterial pressure was 40 mmHg, and the pump flow rate was 550 ml/min. During pulsatile cardiopulmonary bypass, the pump’s base flow was set at 30%, and the pump rate was set at 80, 100, 120, 140, or 150 beats/min. The PUMP START and PUMP STOP timing points were adjusted to produce different pulse-width settings. We were especially interested in evaluating the pre- and postoxygenator extracorporeal circuit pressure (ECP), the oxygenator pressure drop, and the precannula ECP. When used with a pulsatile roller pump, the Capiox produced a significantly lower preoxygenator ECP than the Lilliput (p < 0.001); moreover, the Capiox yielded a significantly lower oxygenator pressure drop (p < 0.001). During nonpulsatile perfusion, the Capiox again produced a lower preoxygenator ECP than the Lilliput (p < 0.001). These results suggest that the Capiox may be more suitable than the Lilliput when the pulsatile flow is employed, and pulsatile flow does not increase the ECP with either oxygenator.Keywords
This publication has 20 references indexed in Scilit:
- Effects of perfusion mode on regional and global organ blood flow in a neonatal piglet modelThe Annals of Thoracic Surgery, 1999
- Evaluation of a Physiologic Pulsatile Pump System for Neonate-lnfant Cardiopulmonary Bypass SupportASAIO Journal, 1999
- Testing neonate-infant membrane oxygenators with the University of Texas neonatal pulsatile cardiopulmonary bypass system in vitroPerfusion, 1998
- The Type of Aortic Cannula and Membrane Oxygenator Affect the Pulsatile Waveform Morphology Produced by a Neonate‐Infant Cardiopulmonary Bypass System In VivoArtificial Organs, 1998
- Regional blood flow during pulsatile cardiopulmonary bypass and after circulatory arrest in an infant modelThe Annals of Thoracic Surgery, 1997
- Design and Performance of a Physiologic Pulsatile Flow Neonate-Infant Cardiopulmonary Bypass System1996
- Oxygenators for Extracorporeal Circulation1995
- Membrane oxygenators: influence of design on performancePerfusion, 1994
- Pulsatile low-flow perfusion for enhanced cerebral protectionThe Annals of Thoracic Surgery, 1993
- To Pulse or Not to PulseThe Annals of Thoracic Surgery, 1978