Sublithographic vertical gold nanogap for label-free electrical detection of protein-ligand binding
- 1 March 2007
- journal article
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 25 (2) , 443-447
Abstract
Label-free electrical detection of protein-ligand binding using a vertical gold nanogap is presented. A sublithographic nanogap was created using a sacrificial ultrathin film deposited by atomic layer deposition (ALD) in a process similar to the formation of a cantilever in microelectromechanical system processing. Due to the atomic precision of the sacrificial thickness by ALD, a nanogap was successfully fabricated. After binding streptavidin to biotin on the gold surface, an electrical current was measured for various voltages. A dramatic current increase was observed in the case of biotin-streptavidin binding in comparison with the other two cases: a control group filled with air and a biotin-only binding group. There was a minimal current change in the cases of the biotin-PBST group, the biotin-BSA group, and the biotin-saturated streptavidin group, as compared with the biotin-streptavidin group. At a concentration of streptavidin , the current difference before and after the protein binding was amplified by approximately 3000-fold with nanogap. Also, the detection sensitivity of the vertical nanogap as the gap size varied was investigated. As the size of biotin-streptavidin binding is the most comparable to nanogap, the highest sensitivity was shown in the gap device. nanogap can be used to detect smaller size of biomolecule than that of biotin streptavidin. This arrayable, two-terminal microdevice could be tested for use on a wide range of other biomolecules.
Keywords
This publication has 9 references indexed in Scilit:
- Theoretical and experimental study towards a nanogap dielectric biosensorBiosensors and Bioelectronics, 2005
- Combined nanogap nanoparticles nanosensor for electrical detection of biomolecular interactions between polypeptidesApplied Physics Letters, 2004
- Sublithographic nanofabrication technology for nanocatalysts and DNA chipsJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 2003
- Protein−Ligand Interactions at Poly(amidoamine) Dendrimer Monolayers on GoldLangmuir, 2002
- Probing Ligand Protein Binding Equilibria with Fluorescence Fluctuation SpectroscopyBiophysical Journal, 2000
- Enzyme-Linked Competitive Binding Assays Based on the Biotin/Avidin InteractionAnalytical Sciences, 1999
- Fluorescence study of the ligand stereospecificity for binding to lumazine proteinEuropean Journal of Biochemistry, 1992
- Homogeneous enzyme-linked competitive binding assay for biotin based on the avidin-biotin interactionAnalytica Chimica Acta, 1988