Dynamic Optimization of a Liquid-Cooled Data Center Based on Hourly Outdoor Air Temperature and Humidity Using a Variable-Frequency Water Pump
Authors:
Open Access
- 20 January 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 20639-20658
Abstract
Current research primarily investigates the safe operating characteristics and energy-saving patterns of liquid-cooled data center chips under varying outdoor temperatures and constant humidity conditions. However, existing dynamic optimization methods overlook the problem of optimizing energy consumption while ensuring safe operation constraints during chip-load dynamic adjustments under the combined effects of dynamically changing temperature and humidity. While keeping servers secure and minimizing energy consumption, this study proposes a dynamic operation strategy that adopts a regression fitting model or a BPNN model combined with a variable-frequency pump for different chip loads based on dynamic weather conditions. The results show that compared with optimal dynamic operation considering only temperature and using a fixed-frequency pump, the proposed strategy using a variable-frequency pump reduces the secondary-side average flow rate by up to 6.77%, the primary-side average flow rate by up to 5.04%, and increases the average energy-saving rate by up to 18.15%. Additionally, with this variable-frequency pump method, dynamic optimization considering both temperature and humidity (rather than temperature alone) increases the primary flow rate by 101.09%, the secondary flow rate by 13.04%, and the energy consumption by 74.29%. It is also found that under variable outdoor temperature-humidity conditions, optimization with a variable-frequency pump differs significantly from optimization considering only dynamic outdoor temperature. Moreover, with this dynamic strategy (incorporating variable outdoor conditions and the variable-frequency pump), optimal operation varies greatly with different chip loads. This study offers an innovative method for the dynamic optimization of data center cooling under variable outdoor temperature and humidity, enabling energy savings while ensuring server safety.Keywords
Funding Information
- Hebei Province major science and technology support plan. Project name?International collaborative research on renewable energy to improve the safety and resilience of the built environment (24294301Z)
- The National Key R&D Program of China (2022YFB4501701)
This publication has 28 references indexed in Scilit:
- Optimal dynamic thermal management for data center via soft actor-critic algorithm with dynamic control interval and combined-value state spaceApplied Energy, 2024
- Real-time optimization of the liquid-cooled data center based on cold plates under different ambient temperatures and thermal loadsApplied Energy, 2024
- Performance analysis of new liquid cooling topology and its impact on data centresApplied Thermal Engineering, 2022
- Optimal thermal management of server cooling system based cooling tower under different ambient temperaturesApplied Thermal Engineering, 2022
- Performance optimization of server water cooling system based on minimum energy consumption analysisApplied Energy, 2021
- Energy saving analysis of evaporative cooling composite air conditioning system for data centersApplied Thermal Engineering, 2021
- Multi-criteria performance optimization for operation of stratum ventilation under heating modeApplied Energy, 2019
- A review of current status of free cooling in datacentersApplied Thermal Engineering, 2017
- Comparative analysis on operation strategies of CCHP system with cool thermal storage for a data centerApplied Thermal Engineering, 2016
- Simulation of a temperature adaptive control strategy for an IWSE economizer in a data centerApplied Energy, 2014