A Right Ventricular Pressure Waveform Based Pulse Contour Cardiac Output Algorithm in Canines
- 8 September 2006
- journal article
- research article
- Published by Springer Nature in Cardiovascular Engineering
- Vol. 6 (3) , 83-92
Abstract
Tracking changes in stroke volume or cardiac output (CO) can be useful in the diagnosis and treatment of various cardiac illnesses. Existing arterial pressure waveform based pulse contour CO algorithms perform poorly during altered systemic hemodynamics. In this study, a right ventricular pressure waveform based pulse contour CO algorithm was developed to estimate the amplitude and duration of a hypothetical triangular flow waveform in the pulmonary artery. This algorithm was tested against gold standard blood flow measurements in ten canines during acute perturbations to preload (inferior vena caval occlusion (IVCO), rapid saline infusion), afterload (descending aortic occlusion (DAO), serotonin, angiotensin II, sodium nitroprusside infusion), and cardiac contractility (dobutamine and propranolol infusion). The algorithm correctly predicted the changes in CO (r 2 = 0.82) that varied from − 45 to 31% of the baseline levels. To explain this finding both the pulmonary arterial (PA) and the ascending aortic (AA) input impedances were modeled as three element windkessels. In the AA the peripheral resistance (from − 61 to 191%), characteristic impedance (from − 59 to 20%) and total arterial compliance (from − 49 to 34%) varied significantly with these perturbations. In contrast, these parameters in the PA changed little. In particular, except serotonin infusion, the characteristic impedance of the PA deviated only 6% (SD/mean) from baseline values. This suggests right ventricular pressure waveform based estimate of CO is possible during acute changes in left ventricular hemodynamics.Keywords
This publication has 23 references indexed in Scilit:
- Development of Implantable Devices for Continuous Ambulatory Monitoring of Central Hemodynamic Values in Heart Failure PatientsPacing and Clinical Electrophysiology, 2005
- Beat-to-beat stroke volume estimation from aortic pressure waveform in conscious rats: comparison of modelsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2001
- A System for Analysis of Arterial Blood Pressure Waveforms in HumansComputers and Biomedical Research, 1997
- Measurement of pulmonary artery diastolic pressure from a right ventricular pressure transducer in patients with heart failureJournal of Cardiac Failure, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Continuous determination of beat to beat stroke volume from aortic pressure pulses in the dog.Circulation Research, 1976
- Pressure methods for estimating right and left ventricular stroke volumesAmerican Journal of Physiology-Legacy Content, 1973
- Pressure and Flow Generated by the Left Ventricle against Different ImpedancesCirculation Research, 1973
- A new technique for measurement of cardiac output by thermodilution in manThe American Journal of Cardiology, 1971
- Estimation of Stroke Volume in the Dog by a Pulse Contour MethodCirculation Research, 1970