Three‐dimensional ultrashort echo time imaging with tricomponent analysis for human cortical bone
- 7 March 2019
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 82 (1) , 348-355
Abstract
Purpose: To investigate tricomponent analysis of human cortical bone using a multipeak fat signal model with 3D ultrashort TE Cones sequences on a clinical 3T scanner.Methods: Tricomponent fitting of bound water, pore water, and fat content using a multipeak fat spectra model was proposed for 3D ultrashort TE imaging of cortical bone. Three‐dimensional ultrashort TE Cones acquisitions combined with tricomponent analysis were used to investigate bound and pore water and fractions, as well as fat and fraction in cortical bone. Feasibility studies were performed on 9 human cortical bone specimens with regions of interest selected from the endosteum to the periosteum in 4 circumferential regions. Microcomputed tomography studies were performed to measure bone porosity and bone mineral density for comparison and validation of the bound and pore water analyses.Results: The oscillation of the signal decay was well‐fitted with the proposed tricomponent model. The sum of the pore water and fat fractions from tricomponent analysis showed a high correlation with microcomputed tomography porosity (R = 0.74, P < 0.01). Estimated bound‐water fraction also demonstrated a high correlation with bone mineral density (R = 0.70, P < 0.01).Conclusion: Tricomponent analysis significantly improves the estimation of bound‐water and pore‐water fractions in human cortical bone.Keywords
Funding Information
- National Natural Science Foundation of China (51607169, 1I01CX001388, I01RX002604)
- GE Healthcare
This publication has 30 references indexed in Scilit:
- Assessment of cortical bone with clinical and ultrashort echo time sequencesMagnetic Resonance in Medicine, 2012
- Ultrashort echo time (UTE) imaging with bi-component analysis: Bound and free water evaluation of bovine cortical bone subject to sequential dryingBone, 2012
- Quantitative ultrashort echo time (UTE) MRI of human cortical bone: Correlation with porosity and biomechanical propertiesJournal of Bone and Mineral Research, 2011
- MR properties of brown and white adipose tissuesJournal of Magnetic Resonance Imaging, 2011
- Non-invasive Predictors of Human Cortical Bone Mechanical Properties: T2-Discriminated 1H NMR Compared with High Resolution X-rayPLOS ONE, 2011
- Analysis of hip geometry by clinical CT for the assessment of hip fracture risk in elderly Japanese womenBone, 2010
- Composition of adipose tissue and marrow fat in humans by 1H NMR at 7 TeslaJournal of Lipid Research, 2008
- Measurements of mobile and bound water by nuclear magnetic resonance correlate with mechanical properties of boneBone, 2008
- Assessment of water distribution changes in human cortical bone by nuclear magnetic resonanceMeasurement Science and Technology, 2007
- Highly Ordered Interstitial Water Observed in Bone by Nuclear Magnetic ResonanceJournal of Bone and Mineral Research, 2005