Molecular Communication Noise and Capacity Analysis for Particulate Drug Delivery Systems
Authors:
- 29 September 2014
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Communications
- Vol. 62 (11) , 3891-3903
Abstract
Particulate Drug Delivery Systems (PDDS) are therapeutic methods that use nanoparticles to achieve their healing effects at the exact time, concentration level of drug nanoparticles, and location in the body, while minimizing the effects on other healthy locations. The Molecular Communication (MC) paradigm, where the transmitted message is the drug injection process, the channel is the cardiovascular system, and the received message is the drug reception process, has been investigated as a tool to study nanoscale biological and medical systems in recent years. In this paper, the various noise effects that cause uncertainty in the cardiovascular system are analyzed, modeled, and evaluated from the information theory perspective. Analytical MC noises are presented to include all end-to-end noise effects, from the drug injection, to the absorption of drug nanoparticles by the diseased cells, in the presence of a time-varying and turbulent blood flow. The PDDS capacity is derived analytically including all these noise effects and the constraints on the drug injection. The proposed MC noise is validated by using the kinetic Monte-Carlo simulation technique. Analytical expressions of the noise and the capacity are derived, and MC is presented as a framework for the optimization of particulate drug delivery systems (PDDS).Keywords
Funding Information
- Samsung Advanced Institute of Technology (SAIT)
- Global Research Outreach (GRO) Program
This publication has 27 references indexed in Scilit:
- Shear stress and the endothelial transport barrierCardiovascular Research, 2010
- Potential role of size and hemodynamics in the efficacy of vascular-targeted spherical drug carriersBiomaterials, 2010
- Design maps for nanoparticles targeting the diseased microvasculatureBiomaterials, 2008
- Models of Flow-Induced Loading on Blood Cells in Laminar and Turbulent Flow, with Application to Cardiovascular Device FlowAnnals of Biomedical Engineering, 2007
- Distribution of wall shear rate throughout the arterial tree: A case studyAtherosclerosis, 2007
- The adhesive strength of non-spherical particles mediated by specific interactionsBiomaterials, 2006
- Molecular Communication through Stochastic Synchronization Induced by Extracellular FluctuationsPhysical Review Letters, 2005
- The genetic basis of variability in drug responsesNature Reviews Drug Discovery, 2002
- Capacity and cutoff rate for Poisson-type channelsIEEE Transactions on Information Theory, 1980
- An approximation theorem for the Poisson binomial distributionPacific Journal of Mathematics, 1960