Electrochemical detection in liquid flow analytical techniques: Characterization and classification (IUPAC Technical Report)
Authors:
- K. TóthKTK. Tóth
- K. StulíkKSK. Stulík
- W. KutnerWKW. Kutner
- Zs. FehérZFZs. Fehér
- E. LindnerELE. Lindner
- 1 January 2004
- journal article
- Published by Walter de Gruyter GmbH in Pure and Applied Chemistry
- Vol. 76 (6) , 1119-1138
Abstract
Liquid flow analytical techniques are classified, and definitions are provided of flow-injection analysis, segmented flow analysis, flow titration, continuous monitoring, liquid chromatography, and capillary electrophoresis. Electrochemical detection and flow through detection cells are characterized with respect to the surface and bulk detection. The detector performance is discussed in terms of its principal analytical parameters, such as detection limit and dynamic concentration range, as well as its dynamic characteristics, such as the response time, sampling frequency, transport lag, and long-term stability. Moreover, different detection modes are critically evaluated, including both potentiostatic and galvano-static techniques. Factors influencing sensitivity and detection limit, which include electronic and hydrodynamic approach, are also discussed. Different detector designs are critically reviewed, and the special features of electrochemical detectors for flow analytical techniques are emphasized.Keywords
This publication has 13 references indexed in Scilit:
- Potentiometric selectivity coefficients of ion-selective electrodes. Part II. Inorganic anions (IUPAC Technical Report)Pure and Applied Chemistry, 2002
- Direct Evidence of Ionic Fluxes Across Ion-Selective Membranes: A Scanning Electrochemical Microscopic and Potentiometric StudyAnalytical Chemistry, 2001
- Sample preconcentration by field amplification stacking for microchip-based capillary electrophoresisElectrophoresis, 2001
- Potentiometric Selectivity Coefficients of Ion-Selective Electrodes. Part I. Inorganic Cations (Technical Report)Pure and Applied Chemistry, 2000
- Analytical aspects of chemically modified electrodes: Classification, critical evaluation and recommendations (IUPAC Recommendations 1998)Pure and Applied Chemistry, 1998
- Chemically modified electrodes: Recommended terminology and definitions (IUPAC Recommendations 1997)Pure and Applied Chemistry, 1997
- Nomenclature for chromatography (IUPAC Recommendations 1993)Pure and Applied Chemistry, 1993
- Definition and determination of response time of ion selective electrodesPure and Applied Chemistry, 1986
- Theoretical considerations on the performance of electrochemical flow-through detectorsAnalytica Chimica Acta, 1980
- The theory of concentration polarisationDiscussions of the Faraday Society, 1947