Abstract
Hyperthermia has been used in conjunction with radiation and chemotherapy for cancer treatment. When using electromagnetic heating, applicators are critical components in contact with or in proximity to patients and can be the determining factor for effective and safe treatment. Tissue absorption of electromagnetic energy is determined by many factors. Three cases are shown to illustrate the complexity of microwave heating: 1) The BSD MA‐151 applicator has good center heating on a muscle‐only phantom as shown in the operation manual. When fat slabs of 0.25, 0.5, 1, and 2 cm thick were added, two hot spots near the periphery of the applicator were evident on all fat surfaces, exposed at 631 MHz. At 915 MHz, the heating was elongated on the surface of the models with 0.25‐ and 2‐cm fat, and two hot spots were observed on the 0.5‐ and 1‐cm fat surfaces. 2) Heating patterns of the Clini‐Therm applicators on a muscle‐only phantom, as indicated in the operations guide, are elliptical with their major axes perpendicular to the electric field. However, when a bolus is used, the elliptical pattern is parallel to the E field. 3) Heating patterns in cylindrical structures were studied with inhomogeneous models of limbs. Arm and thigh models consisting of fat, bone, and muscle material were heated with Clini‐Therm L, M, and MS applicators at 915 MHz. In addition to the geometric effect, the results indicated that placing the applicators with E field parallel to the long axis of cylindrical structures can minimize required power, produce less heating of fats and reduce stray radiation. In conclusion, to apply penetrating microwave or other RF fields for tissue heating, one must simulate the clinical exposure conditions as closely as possible to obtain useful heating patterns. 1992 Wiley‐Liss, Inc.Keywords
This publication has 22 references indexed in Scilit:
- Heating patterns of microwave applicators in inhomogeneous arm and thigh phantomsMedical Physics, 1991
- Effects of fat thickness on heating patterns of the microwave applicator MA-151 at 631 and 915 MHzInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1990
- Evaluation of captive bolus applicatorsMedical Physics, 1990
- RTOG quality assurance guidelines for clinical trials using hyperthermiaInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1990
- Recent Technical Developments in Cancer Hyperthermia1990
- Response of canine oral carcinomas to heat and radiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1987
- Specific absorption rates in simulated tissue media for a 10×10 cm 915-MHz waveguide applicatorMedical Physics, 1987
- Thermographically determined specific absorption rate patterns of 434-MHz applicatorsMedical Physics, 1986
- Formulas for preparing phantom muscle tissue at various radiofrequenciesBioelectromagnetics, 1984
- Electromagnetic Fields and Relative Heating Patterns Due to a Rectangular Aperture Source in Direct Contact with Bilayered Biological TissueIEEE Transactions on Microwave Theory and Techniques, 1971