Development of a Screening Method for the Determination of PCBs in Water Using QuEChERS Extraction and Gas Chromatography-Triple Quadrupole Mass Spectrometry
Authors:
Open Access
- 1 January 2012
- journal article
- Published by Japan Society for Analytical Chemistry in Analytical Sciences
- Vol. 28 (2) , 167
Abstract
A new method has been developed and validated for the simultaneous analysis of 11 polychlorinated biphenyls (PCBs), in water samples at trace levels by gas chromatography coupled to triple quadrupole mass spectrometry (GC-QqQ-MS/MS). Water samples were extracted by the QuEChERS (Quick Easy Cheap Effective Rugged and Safe) method. The QqQ analyzer acquired data in multiple reactions monitoring (MRM), permitting both quantification and confirmation in a single injection with a running time reduced up to 11.0 min. The effect of matrix interferences in extracts on analyte quantification and the identification of PCBs in water samples was deeply studied. The results showed that PCBs were prone to strong matrix interactions in water samples, and the quantification and identification of PCBs were highly affected by a matrix enhancement effect. To evaluate the performance of the method, validation experiments were carried out on water samples at three spiking levels (1.6, 8.0, 40.0 μg L−1). Recovery was in the range of 95 – 109% at 1.6 μg L−1, 90 – 95% at 8.0 μg L−1 and 97 – 102% at 40.0 μg L−1, respectively. Precision values expressed as relative standard deviation (RSD) were lower than 15%. Linearity in the range of 0.5 – 50.0 μg L−1 provided determination coefficients (R2) higher than 0.999 for all compounds. The limits of detection (LODs) for PCBs were ≤0.1 μg L−1 and the limits of quantification (LOQs) ranged from 0.04 to 0.3 μg L−1. The applicability of the proposed method to detect and quantify PCBs has been demonstrated in analyse of 15 real samples.Keywords
This publication has 41 references indexed in Scilit:
- Improving analytical confidence in the determination of PCBs in complex matrices by a sequential GC-MS/MS approachInternational Journal of Environmental Analytical Chemistry, 2008
- Experimental evaluation of the usefulness of feathers as a non-destructive biomonitor for polychlorinated biphenyls (PCBs) using silastic implants as a novel method of exposureEnvironment International, 2007
- Analysis of PCBs in soils and sediments by microwave-assisted extraction, headspace-SPME and high resolution gas chromatography with ion-trap tandem mass spectrometryInternational Journal of Environmental Analytical Chemistry, 2006
- Global uncertainty associated with the analysis of PCBs and chlordanes in drinking water by headspace-SPME-GC/MS/MSInternational Journal of Environmental Analytical Chemistry, 2005
- Persistent organochlorine pollutants in ringed seals and polar bears collected from northern AlaskaScience of The Total Environment, 2002
- Human blood and environmental media screening method for pesticides and polychlorinated biphenyl compounds using liquid extraction and gas chromatography–mass spectrometry analysisJournal of Chromatography B, 2002
- Determination of Polybrominated Diphenyl Ethers and Polychlorinated Biphenyls in Human Adipose Tissue by Large-Volume Injection−Narrow-Bore Capillary Gas Chromatography/Electron Impact Low-Resolution Mass SpectrometryAnalytical Chemistry, 2002
- PCB congeners in precipitation, wash out ratios and depositional fluxes within the Baltic Sea region, EuropeAtmospheric Environment, 2002
- Polychlorinated biphenyl partitioning in the waters of a remote mountain lakeScience of The Total Environment, 2001
- Identification and quantification of polychlorinated biphenyls and some endocrine disrupting pesticides in human adipose tissue from FinlandChemosphere, 2001