The Change in Retentive Values of Locator Attachments and Hader Clips over Time
Authors:
- 3 August 2009
- journal article
- research article
- Published by Wiley in Journal of Prosthodontics
- Vol. 18 (6) , 479-483
Abstract
Purpose: The aim of this study was to examine early changes in retentive values of implant overdenture attachments during multiple pulls. Materials and Methods: Two implant attachment systems (Hader bar and clip, Locator system) were used in this study. The experimental groups were divided into yellow Hader clips, white Locator attachments, and green Locator attachments. Each group consisted of 21 matrix attachments. The attachments were placed into a custom‐made acrylic resin block seated passively on another acrylic block containing a Hader bar or two Locator abutments with different angulations. Each attachment was subjected to 20 consecutive pulls using a universal testing machine. The peak load‐to‐dislodgement of the attachments after each pull was documented, and the percent reduction of the peak load‐to‐dislodgement was calculated. One‐way ANOVA and Tukey's honestly significant difference test were used for data analyses. A p≤ 0.05 was considered significant. Results: There was a significant difference in the percent reduction in peak load‐to‐dislodgement between the attachments after the first pull (p= 0.005) and after the final pull (p= 0.0001). The yellow Hader clips exhibited the least percent reduction in peak load‐to‐dislodgement (6.50 ± 3.59%) after the first pull, followed by the white Locator attachments (8.60 ± 4.42%); the green Locator attachments exhibited the greatest reduction (11.05 ± 4.94%). Conclusion: The results of this in vitro study demonstrate that retentive values of the Locator attachments are reduced significantly after multiple pulls. Although this reduction might not be noticeable to the patient, it is recommended that the clinician place and remove the overdenture multiple times before delivery.Keywords
This publication has 10 references indexed in Scilit:
- The Effect of Denture Cleansing Solutions on the Retention of Yellow Hader Clips: An In Vitro StudyJournal of Prosthodontics, 2007
- Retention Characteristics of Attachment Systems for Implant OverdenturesJournal of Prosthodontics, 2004
- Retention of maxillary implant overdenture bars of different designsThe Journal of Prosthetic Dentistry, 2001
- A 5‐year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: peri‐implant outcome.Clinical Oral Implants Research, 1998
- The effect of simulated function on the retention of bar-clip retained removable prosthesesThe Journal of Prosthetic Dentistry, 1996
- Periodontal aspects of osseointegrated fixtures supporting a partial bridgeJournal of Clinical Periodontology, 1992
- Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue-integrated prosthesesThe Journal of Prosthetic Dentistry, 1988
- A 15-year study of osseointegrated implants in the treatment of the edentulous jawInternational Journal of Oral Surgery, 1981
- Alveolar bone loss in overdentures: A 5-year studyThe Journal of Prosthetic Dentistry, 1978
- The continuing reduction of the residual alveolar ridges in complete denture wearers: A mixed-longitudinal study covering 25 yearsThe Journal of Prosthetic Dentistry, 1972