What to do with device‐detected atrial high‐rate episodes: Summary of the evidences
- 19 December 2021
- journal article
- review article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 45 (2) , 250-261
Abstract
Cardiac implanted electronic devices (CIEDs), that perform atrial sensing via an atrial electrode, commonly detect self-terminating atrial arrhythmias. Nomenclature of these arrhythmias is defined as atrial high-rate episodes (AHREs) and subclinical atrial fibrillation (SCAF). We have provided a comprehensive summation of the trials regarding the incidence and adverse outcomes of AHREs. The reported incidence of AHRE varies considerably (approximately 10% to %70) between studies depending on the definition of AHRE, duration of follow-up and the clinical profile of the population. There is increasing evidence related with the association between AHREs’ and stroke and/or systemic embolism. However, risk of stroke and/or systemic embolism seems to be less than the risk associated with clinical AF. There is still lack of sufficient evidence related with oral anticoagulation (OAC) in patients with AHRE to reduce thromboembolic risk. Although, the strongest association of OAC treatment with reduction in stroke has been reported to be observed among patients with device detected SCAF episodes of >24 hours; it is still questionable whether AHRE is a direct cause of thromboembolic event or just a marker of increased risk. Results of ongoing randomized clinical trials (NOAH-AFNET 6 and ARTESIA) will provide robust evidence on effect of OAC therapy on AHREs. This article is protected by copyright. All rights reservedKeywords
This publication has 50 references indexed in Scilit:
- Pacemaker-Detected Atrial Fibrillation in Patients With Pacemakers: Prevalence, Predictors, and Current Use of Oral AnticoagulationCanadian Journal of Cardiology, 2013
- Detection of Previously Undiagnosed Atrial Fibrillation in Patients With Stroke Risk Factors and Usefulness of Continuous Monitoring in Primary Stroke PreventionThe American Journal of Cardiology, 2012
- Subclinical Atrial Fibrillation and the Risk of StrokeNew England Journal of Medicine, 2012
- Detection of atrial high-rate events by continuous Home Monitoring: clinical significance in the heart failure-cardiac resynchronization therapy populationEP Europace, 2011
- Incidence of Newly Detected Atrial Arrhythmias via Implantable Devices in Patients With a History of Thromboembolic EventsStroke, 2010
- Frequency, Duration, and Predictors of Newly-Diagnosed Atrial Fibrillation Following Dual-Chamber Pacemaker Implantation in Patients Without a Previous History of Atrial FibrillationThe American Journal of Cardiology, 2008
- Newly Detected Atrial Fibrillation Following Dual Chamber Pacemaker ImplantationJournal of Cardiovascular Electrophysiology, 2006
- Incidence of Atrial Tachyarrhythmias in Pacemaker Patients: Results from the Balanced Evaluation of Atrial Tachyarrhythmias in Stimulated Patients (BEATS) StudyPacing and Clinical Electrophysiology, 2006
- Prevalence and clinical implications of atrial fibrillation episodes detected by pacemaker in patients with sick sinus syndromeHeart, 2005
- Prevalence of supraventricular arrhythmias from the automated analysis of data stored in the DDD pacemakers of 617 patients: the AIDA studyPacing and Clinical Electrophysiology, 1998