In situ electrochemical contact angle study of hemoglobin and hemoglobin–Fe3O4 nanocomposites
- 1 November 2006
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 386 (7-8) , 2075-2079
Abstract
The electrochemical redox-induced contact angle changes of hemoglobin droplets in the absence and presence of tetraheptylammonium-capped Fe3O4 nanoparticles have been explored by using in situ electrochemical contact angle measurements. The results indicate that the electrochemical redox process may lead to some structure changes of hemoglobin (Hb), which could further induce the hydrophobic-to-hydrophilic changes of the relative droplets. Our observations demonstrate that hemoglobin could self-assemble on the surface of the functionalized Fe3O4 nanoparticles as Hb–Fe3O4 nanocomposites, which may contribute to much more significant change of the electrochemical redox-induced contact angle values than that with free nano-Fe3O4. These results suggest that in situ electrochemical contact angle measurements could be readily applied as a new and convenient method to detect some specific biological process. Schematic drawing of the possible process and contact angle changes for the self-assembly of hemoglobin on the tetraheptylammonium-capped Fe3O4 nanoparticlesKeywords
This publication has 19 references indexed in Scilit:
- Poly(ethylene glycol) Surface Coated Magnetic ParticlesMacromolecular Rapid Communications, 2005
- Electromechanics of a Redox-Active Rotaxane in a Monolayer Assembly on an ElectrodeJournal of the American Chemical Society, 2004
- Magnetically Amplified DNA Assays (MADA): Sensing of Viral DNA and Single‐Base Mismatches by Using Nucleic Acid Modified Magnetic ParticlesAngewandte Chemie International Edition, 2003
- Potential-controlled molecular machinery of bipyridinium monolayer-functionalized surfaces: an electrochemical and contact angle analysisElectronic supplementary information (ESI) available: experimental details on the electrode modification, electrochemical and contact angle measurements. See http://www.rsc.org/suppdata/cc/b3/b303845a/Chemical Communications, 2003
- Electrochemical stripping detection of DNA hybridization based on cadmium sulfide nanoparticle tagsElectrochemistry Communications, 2002
- Direct Electron Transfer for Heme Proteins Assembled on Nanocrystalline TiO2 FilmElectroanalysis, 2001
- Magneto-Switchable BioelectrocatalysisJournal of the American Chemical Society, 2000
- Preparation and Properties of Magnetite and Polymer Magnetite NanoparticlesLangmuir, 1999
- Direct binding of protein to magnetic particlesBiotechnology Techniques, 1997
- Anion Binding to Mitochondrial Cytochromes c Studied through ElectrochemistryEuropean Journal of Biochemistry, 1996