Removing ocular artifact of EEG signal using SOBI-RO on motor imagery experiment
- 1 August 2014
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 303-308
Abstract
Eye blinking known as ocular artifact cause changes to the electric fields over the scalp and as a result, EEG recordings are often significantly distorted and their interpretation problematic. In this paper, an algorithm using second order blind identification with robust orthogonalization (SOBI-RO) is used to remove the ocular artifact in a motor imagery experiment. Simulation results shows that the ocular artifacts are significantly removed and the sources of the brain activity are clearly identified. The identification performance using signal to distortion ratio value about 68.88% is achieved.Keywords
This publication has 10 references indexed in Scilit:
- Improvement of BCI Performance Through Nonlinear Independent Component Analysis ExtractionJournal of Computers, 2014
- A Comparison of Extraction Techniques for the Rapid Electroencephalogram-P300 SignalsAdvanced Science Letters, 2014
- Automatic Removal of Ocular Artifact from EEG with DWT and ICA MethodApplied Mathematics & Information Sciences, 2013
- A Comparison of EEG Processing Methods to Improve the Performance of BCIInternational Journal of Signal Processing Systems, 2013
- Real-time feature extraction of P300 component using adaptive nonlinear principal component analysisBioMedical Engineering OnLine, 2011
- An efficient P300-based brain–computer interface for disabled subjectsJournal of Neuroscience Methods, 2008
- EEG Signal Processing2007
- Adaptive Blind Signal and Image Processing2002
- Independent Component Analysis2001
- The quantitative extraction and topographic mapping of the abnormal components in the clinical EEGElectroencephalography and Clinical Neurophysiology, 1991