Simultaneous recovery and desulfurization of bitumen from oil sand using ultrasound irradiation

Authors:

Abstract
Oil sand contains bitumen, which includes a high percentage of sulfur. Before using bitumen as a fuel, it must be recovered from oil sand and desulfurized. Currently, bitumen is recovered from oil sand using hot water (300 °C). Both of these processes consume significant amounts of energy. In this study, we demonstrate the simultaneous recovery and desulfurization of bitumen from oil sand using oxidative desulfurization with ultrasonic irradiation and tetrahydrofuran at 20 °C. We successfully recovered 88% of the bitumen from oil sand and removed 42% of the sulfur from the bitumen.

This publication has 26 references indexed in Scilit: