Compliant Control of Single Tendon-Sheath Actuators Applied to a Robotic Manipulator
Open Access
- 12 February 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 37361-37371
Abstract
Tendon-sheath actuators (TSAs), similar to Bowden cable-based series elastic actuators (SEAs), have a wide range of applications in robots. However, when applying them to manipulators, force sensors cannot be mounted due to limited space. Therefore, this paper proposes a new method for compliant control based on a dual encoder, and the existing transmission model was improved by considering the joint torque. To validate the proposed method, experimental setups composed of a motor, a tendon-sheath component, a robotic joint, force sensors, and position sensors are established. The transmission processes are interpreted clearly through a position control mode. Parameter identifications without external disturbance force are conducted to acquire the ideal transmission model, and the error value between the experiment data and the fitted curve is measured. The availability of the presented scheme is verified by compliant control experiments, including collision detection and hand guiding, and the frequency characteristics of the actuator are analyzed. The results show that the function can be realized without force and torque sensors during the whole process.Keywords
This publication has 32 references indexed in Scilit:
- An index finger exoskeleton with series elastic actuation for rehabilitation: Design, control and performance characterizationThe International Journal of Robotics Research, 2015
- A Review of Algorithms for Compliant Control of Stiff and Fixed-Compliance RobotsIEEE/ASME Transactions on Mechatronics, 2015
- Transmission Model and Compensation Control of Double-Tendon-Sheath Actuation SystemIEEE Transactions on Industrial Electronics, 2014
- Torque Mode Control of a Cable-Driven Actuating System by Sensor FusionJournal of Dynamic Systems, Measurement, and Control, 2013
- Tendon sheath analysis for estimation of distal end force and elongation for sensorless distal endRobotica, 2010
- Robotic system for no‐scar gastrointestinal surgeryThe International Journal of Medical Robotics and Computer Assisted Surgery, 2008
- The DLR lightweight robot: design and control concepts for robots in human environmentsIndustrial Robot: the international journal of robotics research and application, 2007
- A Series Elastic- and Bowden-Cable-Based Actuation System for Use as Torque Actuator in Exoskeleton-Type RobotsThe International Journal of Robotics Research, 2006
- Series elastic actuators2002
- Input-dependent stability of joint torque control of tendon-driven robot handsIEEE Transactions on Industrial Electronics, 1992