Evaluation of Biological Properties In-Vivo of Poly(L-Lactide-Coglycolide) Composites Containing Bioactive Glass
Authors:
- 1 February 2013
- journal article
- research article
- Published by SAGE Publications in Polymers and Polymer Composites
- Vol. 21 (2) , 79-84
Abstract
To evaluate the biological safety of composite materials based on poly(L-lactide-co-glycolide) (PLGA) and bioactive glass (BG), which have a potential application in tissue engineering, the in-vivo biological properties were investigated by applying the micronucleus test, acute systemic toxicity test, haemolytic test and pyrogen measurement. The results indicated that the PLGA/BG composite showed no genetic toxicity; there was no toxicosis or death observed in the acute systemic toxicity test. The haemolytic test suggested that the PLGA/BG composite, with a haemolytic index of 0.281%, did not have an obvious haemolytic reaction. In addition, the PLGA/BG composite materials showed no pyrogen reaction. Therefore, PLGA/BG composite materials could be promising candidate biomedical materials for bone tissue engineering.Keywords
This publication has 18 references indexed in Scilit:
- Study on the Cytotoxicity In Vitro of Composite Materials Based on Poly(L-Lactide-Co-Glycolide) and Bioactive GlassMaterials Science Forum, 2011
- The Preparation and Properties of Bioactive Composites Based on Modification Bioactive Glass and Poly(Lactide-Co-Glycolide)Polymer-Plastics Technology and Engineering, 2010
- Fabrication of Degradable Bone-Like Substitutes Based on Poly-L-lactide and β-tricalcium PhosphateJournal of Macromolecular Science, Part B, 2010
- Mineralization and osteoblast response to bioactive glassin vitroJournal of Medical Engineering & Technology, 2010
- Evaluation of In-Vitro Cytotoxicity of Composite Materials Composed of Poly-L-lactic Acid and ?-Tricalcium PhosphatePolymer-Plastics Technology and Engineering, 2010
- Assessment of Cytocompatibility of Bulk Modified Poly-L-lactic Acid BiomaterialsPolymer-Plastics Technology and Engineering, 2009
- Effects of Surface Modification on the Properties of Poly(lactide-co-glycolide) Composite MaterialsPolymer-Plastics Technology and Engineering, 2009
- Preparation and cell affinity of microtubular orientation-structured PLGA(70/30) blood vessel scaffoldBiomaterials, 2008
- Preparation and Properties of Bioactive Composite Based on Bioactive Glass and Poly-L-LactidePolymer-Plastics Technology and Engineering, 2008
- In vitro and in vivo behavior of self‐reinforced bioabsorbable polymer and self‐reinforced bioabsorbable polymer/bioactive glass compositesJournal of Biomedical Materials Research Part A, 2004