Identifying Subjects at Risk for Diaphragm Atrophy During Mechanical Ventilation Using Routinely Available Clinical Data
Authors:
- 8 December 2020
- journal article
- research article
- Published by SAGE Publications in Respiratory Care
- Vol. 66 (4) , 551-558
Abstract
BACKGROUND: Diaphragmatic respiratory effort during mechanical ventilation is an important determinant of patient outcome, but direct measurement of diaphragmatic contractility requires specialized instrumentation and technical expertise. We sought to determine whether routinely collected clinical variables can predict diaphragmatic contractility and stratify the risk of diaphragm atrophy. METHODS: We conducted a secondary analysis of a prospective cohort study on diaphragm ultrasound in mechanically ventilated subjects. Clinical variables, such as breathing frequency, ventilator settings, and blood gases, were recorded longitudinally. Machine learning techniques were used to identify variables predicting diaphragm contractility and stratifying the risk of diaphragm atrophy (> 10% decrease in thickness from baseline). Performance of the variables was evaluated in mixed-effects logistic regression and random-effects tree models using the area under the receiver operating characteristic curve. RESULTS: Measurements were available for 761 study days in 191 subjects, of whom 73 (38%) developed diaphragm atrophy. No routinely collected clinical variable, alone or in combination, could accurately predict either diaphragm contractility or the development of diaphragm atrophy (model area under the receiver operating characteristic curve 0.63–0.75). The risk of diaphragm atrophy was not significantly different according to the presence or absence of patient-triggered breaths (38.3% vs 38.6%; odds ratio 1.01, 95% CI 0.05–2.03). Diaphragm thickening fraction < 15% during either of the first 2 d of the study was associated with a higher risk of atrophy (44.6% vs 26.1%; odds ratio 2.28, 95% CI 1.05–4.95). CONCLUSIONS: Diaphragmatic contractility and the risk of diaphragm atrophy could not be reliably determined from routinely collected clinical variables and ventilator settings. A single measurement of diaphragm thickening fraction measured within 48 h of initiating mechanical ventilation can be used to stratify the risk of diaphragm atrophy during mechanical ventilation.Keywords
This publication has 37 references indexed in Scilit:
- Driving Pressure and Survival in the Acute Respiratory Distress SyndromeThe New England journal of medicine, 2015
- The Application of Esophageal Pressure Measurement in Patients with Respiratory FailureAmerican Journal of Respiratory and Critical Care Medicine, 2014
- Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilationThorax, 2013
- Spontaneous Effort Causes Occult Pendelluft during Mechanical VentilationAmerican Journal of Respiratory and Critical Care Medicine, 2013
- Estimation of Patient’s Inspiratory Effort From the Electrical Activity of the Diaphragm*Critical Care Medicine, 2013
- Mechanical Ventilation-Induced Reverse-Triggered BreathsChest, 2013
- Diaphragm dysfunction assessed by ultrasonography: Influence on weaning from mechanical ventilation*Critical Care Medicine, 2011
- RE-EM trees: a data mining approach for longitudinal and clustered dataMachine Learning, 2011
- pROC: an open-source package for R and S+ to analyze and compare ROC curvesBMC Bioinformatics, 2011
- The Richmond Agitation–Sedation Scale: Validity and Reliability in Adult Intensive Care Unit PatientsAmerican Journal of Respiratory and Critical Care Medicine, 2002