Simultaneous quantification of dilute aqueous solutions of certain polycyclic aromatic hydrocarbons (PAHs) with significant fluorescent spectral overlap using total synchronous fluorescence spectroscopy (TSFS) and N-PLS, unfolded-PLS and MCR-ALS analysis
Authors:
- 6 October 2011
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (11) , 2616-2624
Abstract
The possibility of simultaneous quantification of dilute aqueous solutions of five polycyclic aromatic hydrocarbons (PAHs) with substantial overlap of fluorescence spectra without preseparation was examined by using total synchronous fluorescence spectroscopy (TSFS) with multivariate methods like N-way partial least square (N-PLS), unfolded-PLS and multivariate curve resolution-alternating least square (MCR-ALS) analysis. The PAHs chosen were anthracene, benzo[a]pyrene, chrysene, perylene and pyrene. Two calibration sets were made using different approaches. Even with significant spectral overlap, the N-PLS, unfolded-PLS and MCR-ALS models were found to be robust for the quantification of all five PAHs in the calibration set where the amounts of PAHs were changed with the fixed relative ratio. The second calibration set, which is relatively difficult to analyse, consisted of samples where amounts of PAHs were changed randomly. It was found that even for this set, predictions were satisfactory. The three calibration models based on N-PLS, unfolded-PLS and MCR-ALS in the second set were relatively more robust for chrysene, benzo[a]pyrene and perylene compared to other PAHs. Root mean square error of calibration (RMSEC) and root mean square error of prediction (RMSEP) and regression parameters were calculated for all the three calibration models. The various parameters show that the combination of TSFS and N-PLS, unfolded-PLS and MCR-ALS analysis can be used for the simultaneous quantification of PAHs in water without any preseparation even when there is substantial overlap of fluorescence.Keywords
This publication has 34 references indexed in Scilit:
- Near real-time, on-site, quantitative analysis of PAHs in the aqueous environment using an antibody-based biosensorEnvironmental Toxicology and Chemistry, 2011
- Synchronous fluorescence spectroscopy as a novel tool to enable PAT applications in bioprocessesBiotechnology and Bioengineering, 2011
- Application of Supervised Self-Organizing Maps in Breast Cancer Diagnosis by Total Synchronous Fluorescence SpectroscopyApplied Spectroscopy, 2011
- Synchronous Front‐Face Fluorescence Spectroscopy Coupled with Parallel Factors (PARAFAC) Analysis to Study the Effects of Cooking Time on MeatJournal of Food Science, 2009
- Total Synchronous Fluorescence Spectroscopy Combined with Multivariate Analysis: Method for the Classification of Selected Resins, Oils, and Protein-Based Media Used in PaintingsAnalytical Chemistry, 2009
- Analysis of rainwater dissolved organic carbon compounds using fluorescence spectrophotometryAtmospheric Environment, 2008
- Application of multivariate curve resolution alternating least squares (MCR-ALS) to the quantitative analysis of pharmaceutical and agricultural samplesTalanta, 2008
- Multivariate calibration of polycyclic aromatic hydrocarbon mixtures from excitation–emission fluorescence spectraAnalytica Chimica Acta, 1998
- Multivariate calibration applied to synchronous fluorescence spectrometry. Simultaneous determination of polycyclic aromatic hydrocarbons in water samplesTalanta, 1998
- Synchronous fluorescence spectroscopy of dissolved organic matter in surface waters: Application to airborne remote sensingRemote Sensing of Environment, 1989