Simultaneous Estimation of Input Functions: An Empirical Study
Open Access
- 9 December 2009
- journal article
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 30 (4) , 816-826
Abstract
In neuroreceptor mapping, methods for the estimation of distribution volume require determination of a metabolite-corrected arterial input function. In application, this may be accomplished by collecting arterial blood samples during scanning, adjusting these measurements according to a separate metabolite analysis, and then modeling the resulting concentration data. Although many groups do this routinely, it is invasive and requires considerable effort. Furthermore, both the plasma and the metabolite data are noisy, and thus estimation of kinetic parameters can be affected by this variability. One promising alternative to full-input function modeling is the simultaneous estimation (SIME) approach, in which kinetic parameters and common input function parameters are estimated using results obtained from several regions at once. We investigate the performance of this approach on data from four different radioligands, using various kinetic models, comparing the results with those obtained by estimation using full-input function modeling. Results indicate that SIME provides a promising alternative for all the radioligands considered.Keywords
This publication has 28 references indexed in Scilit:
- Robust estimation of the arterial input function for Logan plots using an intersectional searching algorithm and clustering in positron emission tomography for neuroreceptor imagingNeuroImage, 2008
- An input function estimation method for FDG-PET human brain studiesNuclear Medicine and Biology, 2007
- Image-Derived Input Function for [11C]Flumazenil Kinetic Analysis in Human BrainMolecular Imaging and Biology, 2003
- Estimation of kinetic parameters without input functions: analysis of three methods for multichannel blind identificationIEEE Transactions on Biomedical Engineering, 2002
- Estimation of input function and kinetic parameters using simulated annealing: application in a flow modelIEEE Transactions on Nuclear Science, 2002
- Positron Emission Tomography Compartmental ModelsJournal of Cerebral Blood Flow & Metabolism, 2001
- Noninvasive Quantification of the Cerebral Metabolic Rate for Glucose Using Positron Emission Tomography, 18F-Fluoro-2-Deoxyglucose, the Patlak Method, and an Image-Derived Input FunctionJournal of Cerebral Blood Flow & Metabolism, 1998
- Technical Note. Input Function in PET Brain Studies Using MR-Defined ArteriesJournal of Computer Assisted Tomography, 1997
- Optimization by Simulated AnnealingScience, 1983
- Tomographic measurement of local cerebral glucose metabolic rate in humans with (F‐18)2‐fluoro‐2‐deoxy‐D‐glucose: Validation of methodAnnals of Neurology, 1979