Quantification of cells with specific phenotypes II: Determination of CD4 expression level on reconstituted lyophilized human PBMC labelled with anti-CD4 FITC antibody
Open Access
- 5 February 2015
- journal article
- research article
- Published by Wiley in Cytometry Part A
- Vol. 87 (3) , 254-261
Abstract
This report focuses on the characterization of CD4 expression level in terms of equivalent number of reference fluorophores (ERF). Twelve different flow cytometer platforms across sixteen laboratories were utilized in this study. As a first step the participants were asked to calibrate the fluorescein isothiocyanate (FITC) channel of each flow cytometer using commercially available calibration standard consisting of five populations of microspheres. Each population had an assigned value of equivalent fluorescein fluorophores (EFF denotes a special case of the generic term ERF with FITC as the reference fluorophore). The EFF values were assigned at the National Institute of Standards and Technology (NIST). A surface‐labelled lyophilized cell preparation was provided by the National Institute of Biological Standards and Control (NIBSC), using human peripheral blood mononuclear cells (PBMC) pre‐labeled with a FITC conjugated anti‐CD4 monoclonal antibody. Three PBMC sample vials, provided to each participant, were used for the CD4 expression analysis. The PBMC are purported to have a fixed number of surface CD4 receptors. On the basis of the microsphere calibration, the EFF value of the PBMC samples was measured to characterize the population average CD4 expression level of the PBMC preparations. Both the results of data analysis performed by each participant and the results of centralized analysis of all participants' raw data are reported. Centralized analysis gave a mean EFF value of 22,300 and an uncertainty of 750, corresponding to 3.3% (level of confidence 68%) of the mean EFF value. The next step will entail the measurement of the ERF values of the lyophilized PBMC stained with labels for other fluorescence channels. The ultimate goal is to show that lyophilized PBMC is a suitable biological reference cell material for multicolor flow cytometry and that it can be used to present multicolor flow cytometry measurements in terms of ABC (antibodies bound per cell) units. © 2015 International Society for Advancement of CytometryKeywords
This publication has 25 references indexed in Scilit:
- EuroFlow antibody panels for standardized n-dimensional flow cytometric immunophenotyping of normal, reactive and malignant leukocytesLeukemia, 2012
- Minimal Residual Disease Detection by Flow Cytometry in Adult T-Cell Leukemia/LymphomaAmerican Journal of Clinical Pathology, 2010
- Assessing minimal residual disease in chronic lymphocytic leukemiaCurrent Hematologic Malignancy Reports, 2008
- Toward quantitative fluorescence measurements with multicolor flow cytometryCytometry Part A, 2007
- Discrepancy in measuring CD4 expression on T‐lymphocytes using fluorescein conjugates in comparison with unimolar CD4‐phycoerythrin conjugatesCytometry Part B: Clinical Cytometry, 2007
- Reduced monocyte CD86 expression in postinflammatory immunodeficiencyCritical Care Medicine, 2007
- Monitoring Temporary Immunodepression by Flow Cytometric Measurement of Monocytic HLA-DR Expression: A Multicenter Standardized StudyClinical Chemistry, 2005
- Higher Levels of Surface CD20 Expression on Circulating Lymphocytes Compared With Bone Marrow and Lymph Nodes in B-Cell Chronic Lymphocytic LeukemiaAmerican Journal of Clinical Pathology, 2001
- Determination of CD4 antigen density on cells: Role of antibody valency, avidity, clones, and conjugationCytometry, 1998