A temperature-dependent gain control system for improving the stability of Si-PM-based PET systems
Authors:
- Seiichi YamamotoSYSeiichi Yamamoto
- Junkichi SatomiJSJunkichi Satomi
- Tadashi WatabeTWTadashi Watabe
- Hiroshi WatabeHWHiroshi Watabe
- Yasukazu KanaiYKYasukazu Kanai
- Masao ImaizumiMIMasao Imaizumi
- Eku ShimosegawaESEku Shimosegawa
- Jun HatazawaJHJun Hatazawa
- 8 April 2011
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (9) , 2873-2882
Abstract
The silicon-photomultiplier (Si-PM) is a promising photodetector for the development of new PET systems due to its small size, high gain and relatively low sensitivity to the static magnetic field. One drawback of the Si-PM is that it has significant temperature-dependent gain that poses a problem for the stability of the Si-PM-based PET system. To reduce this problem, we developed and tested a temperature-dependent gain control system for the Si-PM-based PET system. The system consists of a thermometer, analog-to-digital converter, personal computer, digital-to-analog converter and variable gain amplifiers in the weight summing board of the PET system. Temperature characteristics of the Si-PM array are measured and the calculated correction factor is sent to the variable gain amplifier. Without this correction, the temperature-dependent peak channel shifts of the block detector were -55% from 20 °C to 35 °C. With the correction, the peak channel variations were corrected within ±8%. The coincidence count rate of the Si-PM-based PET system was measured using a Na-22 point source while monitoring the room temperature. Without the correction, the count rate inversely changed with the room temperature by 10% for 1.5° C temperature changes. With the correction, the count rate variation was reduced to within 3.7%. These results indicate that the developed temperature-dependent gain control system can contribute to improving the stability of Si-PM-based PET systems.Keywords
This publication has 14 references indexed in Scilit:
- A G-APD based Camera for Imaging Atmospheric Cherenkov TelescopesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- LaBr3:Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving timePhysics in Medicine & Biology, 2010
- Evaluation of Geiger-mode APDs for PET block detector designsPhysics in Medicine & Biology, 2010
- Scintillation and Cherenkov light detection with a 3 mm × 3 mm Silicon PhotoMultiplierNuclear Physics B - Proceedings Supplements, 2009
- Energy, Timing and Position Resolution Studies With 16-Pixel Silicon Photomultiplier Matrices for Small Animal PETIEEE Transactions on Nuclear Science, 2009
- First results in the application of silicon photomultiplier matrices to small animal PETNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Features of Silicon Photo Multipliers: Precision Measurements of Noise, Cross-Talk, Afterpulsing, Detection EfficiencyIEEE Transactions on Nuclear Science, 2009
- Active control of the gain of a Silicon PhotoMultiplierNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- An Investigation Into the Use of Geiger-Mode Solid-State Photomultipliers for Simultaneous PET and MRI AcquisitionIEEE Transactions on Nuclear Science, 2008
- A test of silicon photomultipliers as readout for PETNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005