Impact of subject head motion on quantitative brain 15O PET and its correction by image-based registration algorithm
- 29 January 2013
- journal article
- research article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 27 (4) , 335-345
Abstract
Objective Subject head motion during sequential 15O positron emission tomography (PET) scans can result in artifacts in cerebral blood flow (CBF) and oxygen metabolism maps. However, to our knowledge, there are no systematic studies examining this issue. Herein, we investigated the effect of head motion on quantification of CBF and oxygen metabolism, and proposed an image-based motion correction method dedicated to 15O PET study, correcting for transmission–emission mismatch and inter-scan mismatch of emission scans. Methods We analyzed 15O PET data for patients with major arterial steno-occlusive disease (n = 130) to determine the occurrence frequency of head motion during 15O PET examination. Image-based motion correction without and with realignment between transmission and emission scans, termed simple and 2-step method, respectively, was applied to the cases that showed severe inter-scan motion. Results Severe inter-scan motion (>3 mm translation or >5° rotation) was observed in 27 of 520 adjacent scan pairs (5.2 %). In these cases, unrealistic values of oxygen extraction fraction (OEF) or cerebrovascular reactivity (CVR) were observed without motion correction. Motion correction eliminated these artifacts. The volume-of-interest (VOI) analysis demonstrated that the motion correction changed the OEF on the middle cerebral artery territory by 17.3 % at maximum. The inter-scan motion also affected CBV, CMRO2 and CBF, which were improved by the motion correction. A difference of VOI values between the simple and 2-step method was also observed. Conclusions These data suggest that image-based motion correction is useful for accurate measurement of CBF and oxygen metabolism by 15O PET.Keywords
This publication has 23 references indexed in Scilit:
- Interindividual Variations of Cerebral Blood Flow, Oxygen Delivery, and Metabolism in Relation to Hemoglobin Concentration Measured by Positron Emission Tomography in HumansJournal of Cerebral Blood Flow & Metabolism, 2010
- Movement Correction Method for Human Brain PET Images: Application to Quantitative Analysis of Dynamic 18F-FDDNP ScansJournal of Nuclear Medicine, 2010
- Motion correction of multi-frame PET data in neuroreceptor mapping: Simulation based validationNeuroImage, 2009
- Quantification of Cerebral Blood Flow and Oxygen Metabolism with 3-Dimensional PET and 15O: Validation by Comparison with 2-Dimensional PETJournal of Nuclear Medicine, 2007
- Relationship Between Cerebral Circulatory Reserve and Oxygen Extraction Fraction in Patients With Major Cerebral Artery Occlusive DiseaseStroke, 2006
- Rapid Quantitative Measurement of CMRO2 and CBF by Dual Administration of 15O-Labeled Oxygen and Water During a Single PET Scan—a Validation Study and Error Analysis in Anesthetized MonkeysJournal of Cerebral Blood Flow & Metabolism, 2005
- Changes in the Arterial Fraction of Human Cerebral Blood Volume during Hypercapnia and Hypocapnia Measured by Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 2005
- Correction for head movements in positron emission tomography using an optical motion-tracking systemIEEE Transactions on Nuclear Science, 2002
- Implementation and performance of an optical motion tracking system for high resolution brain PET imagingIEEE Transactions on Nuclear Science, 1999
- Physiological responses to focal cerebral ischemia in humansAnnals of Neurology, 1984