Novel method for measurement of glutathione kinetics in neonates using liquid chromatography coupled to isotope ratio mass spectrometry
- 27 July 2007
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (17) , 2805-2812
Abstract
A novel analytical method using liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) was developed for measuring the fractional synthesis rate (FSR) of glutathione (GSH) in neonates after infusion of [1‐ 13 C]‐glycine as a tracer. After transformation of GSH into GSSG, its dimeric form, the intra‐erythrocytic concentration and 13 C‐isotopic enrichment of GSH were determined using 200 µL of blood. The results showed that, using LC/IRMS, the concentration (range of µmol/mL) was reliably measured using norvaline as internal standard with precision better than 0.1 µmol/mL. In addition, the 13 C‐isotopic enrichment measured in the same run gave reliable values with excellent precision (with standard deviation (sd) lower than 0.3‰) and accuracy (measured between 0 and 2 Atom % Excess (APE)). The inter‐assay repeatability of δ 13 C of norvaline used as internal standard with in vivo samples was assessed at −26.07 ± 0.28‰ with coefficient of variance (CV) at 1.1%. The FSR calculated either with GSH or GSSG showed similar results with slightly higher values for GSSG (41.6 ± 4.7 and 46.5 ± 4.4, respectively). The slightly lower FSR of GSH is probably due to interfering compounds in the biological matrix. Successfully used in a clinical study, this rapid and reliable method opens up a variety of kinetic studies with relatively low administration of tracer infusates, reducing the total cost of the study design. The small volume of blood needed enables studies even in extremely small subjects, such as premature infants, as reported in this study. Copyright © 2007 John Wiley & Sons, Ltd.Keywords
This publication has 29 references indexed in Scilit:
- Liquid Chromatography Coupled to Isotope Ratio Mass Spectrometry: A New Perspective on Honey Adulteration DetectionJournal of Agricultural and Food Chemistry, 2006
- A novel method to determine small intestinal barrier function in human neonates in vivoGut, 2006
- Analysis of amino acid 13 C abundance from human and faunal bone collagen using liquid chromatography/isotope ratio mass spectrometryRapid Communications in Mass Spectrometry, 2006
- Isotope ratio monitoring of small molecules and macromolecules by liquid chromatography coupled to isotope ratio mass spectrometryRapid Communications in Mass Spectrometry, 2005
- A new concept for isotope ratio monitoring liquid chromatography/mass spectrometryRapid Communications in Mass Spectrometry, 2004
- Blood glutathione redox ratio as a parameter of oxidative stress in premature infants with IRDSFree Radical Biology and Medicine, 1994
- High-precision liquid chromatography-combustion isotope ratio mass spectrometryAnalytical Chemistry, 1993
- Glutathione metabolism and its role in hepatotoxicityPharmacology & Therapeutics, 1991
- Glutathione deficiency produced by inhibition of its synthesis, and its reversal; Applications in research and therapyPharmacology & Therapeutics, 1991
- Stable isotope dilution analysis of cystine in granulocyte suspensions as cysteine: A powerful method for the diagnosis, the follow-up, and treatment of patients with cystinosisClinica Chimica Acta, 1990