Randomized Study of Temporary Hemodialysis Catheters
- 1 January 2002
- journal article
- research article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 25 (1) , 40-44
Abstract
Temporary catheters are still essential for acute dialysis access but their performance has not been compared in randomized trials. We conducted a randomized trial of our standard catheter and a newly designed catheter. The primary outcome was maximized blood flow over the entire use of the catheter. Seventy-six patients provided maximum blood flows. The new catheter provided an average blood flow of 349 ml/min and the standard catheter provided flows of 320 ml/mm (p=0.09). Lumen reversal occurred in 56.8% of dialysis sessions with the standard catheter compared to 27.4% with the new catheter (p<0.001). Left-sided internal jugular catheters and catheters inserted in females provided 103 ml/min and 36 ml/min less blood flow, respectively, compared to right sided catheters and catheters placed in males. Approximately 20% of catheters were removed for poor blood flow. Left sided catheters and catheters in females were more likely to need removal for malfunction but catheter design did not influence removal rates.Keywords
This publication has 16 references indexed in Scilit:
- The hemodialysis catheter conundrum: Hate living with them, but can’t live without themKidney International, 1999
- Initial performance of Tesio hemodialysis catheters.Journal of Vascular and Interventional Radiology, 1999
- Polyurethane Catheters for Long‐Term Hemodialysis AccessArtificial Organs, 1997
- A Comparison of the Dual Lumen and Coaxial Catheters for Temporary Hemodialysis AccessThe International Journal of Artificial Organs, 1997
- Long-term vascular access for hemodialysis using silicon duallumen catheters with guidewire replacement of catheters for technique salvageAmerican Journal of Kidney Diseases, 1997
- Factors and complications affecting catheter and technique survival with permanent single-lumen dialysis cathetersNephrology Dialysis Transplantation, 1994
- Factors Affecting Delivery of High-Efficiency Dialysis Using Temporary Vascular AccessAmerican Journal of Kidney Diseases, 1993
- Use of a Silicone Catheter With a Dacron Cuff for Dialysis Short-Term Vascular AccessAmerican Journal of Kidney Diseases, 1988
- Prospective Evaluation of a Dacron Cuffed Hemodialysis Catheter for Prolonged UseAmerican Journal of Kidney Diseases, 1988
- Comparison of Coaxial and Side-By-Side Double Lumen Subclavian Catheters With the Single Lumen CatheterAmerican Journal of Kidney Diseases, 1986