Kirschner wire placement in scaphoid bones using fluoroscopic navigation: a cadaver study comparing conventional techniques with navigation
- 24 April 2008
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 4 (2) , 165-173
Abstract
Background: During scaphoid fixation, a pin guide is first inserted along the axis of the scaphoid, and then a cannulated screw is inserted around the pin guide. At least, the pinguide is removed. To verify the position of the pin guide, fluoroscopy is typically used, with the disadvantage of irradiation. Thus, it is impossible to visualize the pin guide in more than one view simultaneously. The goal of this study was to compare two pin guide placement techniques in scaphoid fixation: conventional (CF) vs. fluoroscopic navigation (FN).Methods: Eleven upper limbs of cadavers were divided into two groups. The CF group included four scaphoids which were to be fixed with pin guide. The FN group included seven scaphoids which were to be fixed with the same technique under FN.Results: The accuracy of screw insertion in both groups does not differ. In the CF group, the X‐ray exposure time is four times higher. The total duration of the surgical procedure is slightly higher in the FN group.Conclusions: We are of the opinion that FN could be applied in clinical practice and could offer significant benefits in the treatment of fixation of the scaphoid. Copyright © 2008 John Wiley & Sons, Ltd.Keywords
This publication has 15 references indexed in Scilit:
- Die navigierte ScaphoidschraubeDer Unfallchirurg, 2007
- Le vissage percutané du scaphoïde assisté par ordinateur : étude expérimentaleChirurgie de la Main, 2005
- The Morphological and Morphometric Features of the ScaphoidJournal of Hand Surgery (European Volume), 2004
- Minimally Invasive Fixation versus Conservative Treatment of Undisplaced Scaphoid Fractures: A Cost-Effectiveness StudyJournal of Hand Surgery (European Volume), 2004
- Central screw placement in percutaneous screw scaphoid fixation: a cadaveric comparison of proximal and distal techniquesThe Journal of Hand Surgery, 2004
- Minimally invasive management of scaphoid fracturesOperative Techniques in Plastic and Reconstructive Surgery, 2002
- Percutaneous Cannulated Screw Fixation of Acute Scaphoid Waist FractureJournal of Hand Surgery (European Volume), 2002
- Anatomic placement of the Herbert-Whipple screw in scaphoid fractures: A cadaver studyThe Journal of Hand Surgery, 2001
- Percutaneous Fixation of Scaphoid FracturesJournal of Hand Surgery (European Volume), 1999
- Percutaneous Iliosacral Screw Placement Using Image Guided TechniquesClinical Orthopaedics and Related Research, 1998