Comprehensive Neonatal Cardiac, Feed and Wrap, Non‐contrast, Non‐sedated, Free‐breathing Compressed Sensing 4D Flow MRI Assessment
Open Access
- 6 July 2022
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 57 (3) , 789-799
Abstract
Background: Cardiac MRI is an important imaging tool in congenital cardiac disease, but its use has been limited in the neonatal population as general anesthesia has been needed for breath‐holding. Technological advances in four‐dimensional (4D) flow MRI have now made nonsedated free‐breathing acquisition protocols a viable clinical option, but the method requires prospective validation in neonates.Purpose: To test the feasibility of compressed sensing (CS) 4D flow MRI in the neonatal population and to compare with standard previously validated two‐dimensional (2D) phase‐contrast (PC) flow MRI.Study type: Prospective, cohort, image quality.Population: A total of 14 healthy neonates (median [range] age: 2.5 [0–80] days; 8 male).Field Strength and Sequence: Noncontrast 2D cine gradient echo sequence with through‐plane velocity encoding (PC) sequence and compressed sensing (CS) three‐dimensional (3D), time‐resolved, cine phase‐contrast MRI with 3D velocity‐encoding (4D flow MRI) at 3 T.Assessment: Aortic 2D PC, and aortic, pulmonary trunk and superior vena cava CS 4D flow MRI were acquired using the feed and wrap technique (nonsedated) and quantified using commercially available software. Aortic flow and peak velocity were compared between methods. Internal consistency of 4D flow MRI was determined by comparing mean forward flow of the main pulmonary artery (MPA) vs. the sum of left and right pulmonary artery flows (LPA and RPA) and by comparing mean ascending aorta forward flow (AAo) vs. the sum of superior vena cava (SVC) and descending aorta flows (DAo).Statistical Tests: Flow and peak‐velocity comparisons were assessed using paired t‐tests, with P < 0.05 considered significant, and Bland–Altman analysis. Interobserver and intraobserver agreement and internal consistency were analyzed by intraclass correlation co‐efficient (ICC).Results: There was no statistically significant difference between ascending aortic forward flow between 2D PC and CS 4D Flow MRI (P = 0.26) with a bias of 0.11 mL (−0.59 to 0.82 mL) nor peak velocity (P = 0.11), with a bias of −5 cm/sec and (−26 to 16 cm/sec). There was excellent interobserver and intraobserver agreement for each vessel (interobserver ICC: AAo 1.00; DAo 0.94, SVC 0.90, MPA 0.99, RPA 0.98, LPA 0.96; intraobserver ICC: AAo 1.00; DAo 0.99, SVC 0.98, MPA 1.00, RPA 1.00, LPA 0.99). Internal consistency measures showed excellent agreement for both mean forward flow of main pulmonary artery vs. the sum of left and right pulmonary arteries (ICC: 0.95) and mean ascending aorta forward flow vs. the sum of superior vena cava and descending aorta flows (ICC: 1.00).Conclusion: Sedation‐free neonatal feed and wrap MRI is well tolerated and feasible. CS 4D flow MRI quantification is similar to validated 2D PC free‐breathing imaging with excellent interobserver and intraobserver agreement.Evidence Level: 1Technical Efficacy: Stage 2Keywords
Funding Information
- University of Leeds
- National Institute for Health and Care Research
This publication has 36 references indexed in Scilit:
- Venous and arterial flow quantification are equally accurate and precise with parallel imaging compressed sensing 4D phase contrast MRIJournal of Magnetic Resonance Imaging, 2012
- Rapid Pediatric Cardiac Assessment of Flow and Ventricular Volume With Compressed Sensing Parallel Imaging Volumetric Cine Phase-Contrast MRIAmerican Journal of Roentgenology, 2012
- Systemic-to-pulmonary collateral flow in patients with palliated univentricular heart physiology: measurement using cardiovascular magnetic resonance 4D velocity acquisitionJournal of Cardiovascular Magnetic Resonance, 2012
- 4D cardiovascular magnetic resonance velocity mapping of alterations of right heart flow patterns and main pulmonary artery hemodynamics in tetralogy of FallotJournal of Cardiovascular Magnetic Resonance, 2012
- The Role of Cardiovascular Magnetic Resonance in Pediatric Congenital Heart DiseaseJournal of Cardiovascular Magnetic Resonance, 2011
- Functional cardiac MRI in preterm and term newbornsArchives of Disease in Childhood - Fetal and Neonatal Edition, 2010
- Comparison of neonatal MRI examinations with and without an MR-compatible incubator: Advantages in examination feasibility and clinical decision-makingEuropean Journal of Paediatric Neurology, 2010
- Flow‐sensitive four‐dimensional cine magnetic resonance imaging for offline blood flow quantification in multiple vessels: A validation studyJournal of Magnetic Resonance Imaging, 2010
- The Challenge of Congenital Heart Disease Worldwide: Epidemiologic and Demographic FactsSeminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual, 2010
- Anaesthesia considerations for cardiac MRI in infants and small childrenPediatric Anesthesia, 2004