Minimal Tissue Reaction after Chronic Subdural Electrode Implantation for Fully Implantable Brain–Machine Interfaces
Open Access
Abstract
There is a growing interest in the use of electrocorticographic (ECoG) signals in brain–machine interfaces (BMIs). However, there is still a lack of studies involving the long-term evaluation of the tissue response related to electrode implantation. Here, we investigated biocompatibility, including chronic tissue response to subdural electrodes and a fully implantable wireless BMI device. We implanted a half-sized fully implantable device with subdural electrodes in six beagles for 6 months. Histological analysis of the surrounding tissues, including the dural membrane and cortices, was performed to evaluate the effects of chronic implantation. Our results showed no adverse events, including infectious signs, throughout the 6-month implantation period. Thick connective tissue proliferation was found in the surrounding tissues in the epidural space and subcutaneous space. Quantitative measures of subdural reactive tissues showed minimal encapsulation between the electrodes and the underlying cortex. Immunohistochemical evaluation showed no significant difference in the cell densities of neurons, astrocytes, and microglia between the implanted sites and contralateral sites. In conclusion, we established a beagle model to evaluate cortical implantable devices. We confirmed that a fully implantable wireless device and subdural electrodes could be stably maintained with sufficient biocompatibility in vivo.Keywords
Funding Information
- National Institute of Information and Communications Technology (Research and development of technologies for high-speed wireless communication from inside to outside of the body and large-scale data analyses of brain information and their application for BMI)
- Japan Society for the Promotion of Science (18H04166)
- Osaka University (The grant for supporting researchers to establish a start-up company)
This publication has 46 references indexed in Scilit:
- Long-Term Measurement of Impedance in Chronically Implanted Depth and Subdural Electrodes During Responsive Neurostimulation in HumansBrain Stimulation, 2013
- An Electrocorticographic Brain Interface in an Individual with TetraplegiaPLOS ONE, 2013
- High-performance neuroprosthetic control by an individual with tetraplegiaThe Lancet, 2013
- Pathologic Findings Associated With Invasive EEG Monitoring for Medically Intractable EpilepsyAmerican Journal of Clinical Pathology, 2012
- Decoding vowels and consonants in spoken and imagined words using electrocorticographic signals in humansJournal of Neural Engineering, 2011
- Temporal progression of the host response to implanted poly(ethylene glycol)‐based hydrogelsJournal of Biomedical Materials Research Part A, 2011
- Evolution of brain–computer interface: action potentials, local field potentials and electrocorticogramsCurrent Opinion in Neurobiology, 2010
- An alginate hydrogel dura mater replacement for use with intracortical electrodesJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2010
- First long term in vivo study on subdurally implanted Micro-ECoG electrodes, manufactured with a novel laser technologyBiomedical Microdevices, 2010
- Optimal spacing of surface electrode arrays for brain–machine interface applicationsJournal of Neural Engineering, 2010