Measurement of Signal-to-Noise and Contrast-to-Noise in the fBIRN Multicenter Imaging Study
Open Access
- 10 March 2006
- journal article
- research article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 19 (2) , 140-147
Abstract
The ability to analyze and merge data across sites, vendors, and field strengths depends on one's ability to acquire images with the same image quality including image smoothness, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). SNR can be used to compare different magnetic resonance scanners as a measure of comparability between the systems. This study looks at the SNR and CNR ratios in structural fast spin-echo T2-weighted scans acquired in five individuals across ten sites that are part of Functional Imaging Research of Schizophrenia Testbed Biomedical Informatics Research Network (fBIRN). Different manufacturers, field strengths, gradient coils, and RF coils were used at these sites. The SNR of gray matter was fairly uniform (41.3–43.3) across scanners at 1.5 T. The higher field scanners produced images with significantly higher SNR values (44.5–108.7 at 3 T and 50.8 at 4 T). Similar results were obtained for CNR measurements between gray/white matter at 1.5 T (9.5–10.2), again increasing at higher fields (10.1–28.9 at 3 T and 10.9 at 4 T).Keywords
This publication has 17 references indexed in Scilit:
- Reproducibility of Functional MR Imaging: Preliminary Results of Prospective Multi-institutional Study Performed by Biomedical Informatics Research NetworkRadiology, 2005
- A Prospective Multi-institutional Study of the Reproducibility of fMRI: A Preliminary Report from the Biomedical Informatics Research NetworkLecture Notes in Computer Science, 2004
- Signal Intensity Artifacts in Clinical MR ImagingRadioGraphics, 2000
- MR Imaging of Human Brain at 3.0 T: Preliminary Report on Transverse Relaxation Rates and Relation to Estimated Iron ContentRadiology, 1999
- Multimodality image registration by maximization of mutual informationIEEE Transactions on Medical Imaging, 1997
- In vivo measurement of T2 distributions and water contents in normal human brainMagnetic Resonance in Medicine, 1997
- MR relaxation times in human brain: measurement at 4 T.Radiology, 1996
- 5196797 Method of correcting an asymmetry in an NMR radio frequency coil and an improved radio frequency coil having N-fold symmetry and reduced eddy currentMagnetic Resonance Imaging, 1993
- Image processing for the study of brain structure and function: problems and programsThe Journal of Neuropsychiatry and Clinical Neurosciences, 1992
- A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1–100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and ageMedical Physics, 1984