Femoral and tibial component rotation in total knee arthroplasty
Author:
- 1 November 2013
- journal article
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 95-B (11_Supple_) , 140-143
Abstract
At least four ways have been described to determine femoral component rotation, and three ways to determine tibial component rotation in total knee replacement (TKR). Each method has its advocates and each has an influence on knee kinematics and the ultimate short and long term success of TKR. Of the four femoral component methods, the author prefers rotating the femoral component in flexion to that amount that establishes a stable symmetrical flexion gap. This judgement is made after the soft tissues of the knee have been balanced in extension.Of the three tibial component methods, the author prefers rotating the tibial component into congruency with the established femoral component rotation with the knee is in extension. This yields a rotationally congruent articulation during weight-bearing and should minimise the torsional forces being transferred through a conforming tibial insert, which could lead to wear to the underside of the tibial polyethylene. Rotating platform components will compensate for any mal-rotation, but can still lead to pain if excessive tibial insert rotation causes soft-tissue impingement.Cite this article: Bone Joint J 2013;95-B, Supple A:140–3.Keywords
This publication has 21 references indexed in Scilit:
- Femoral Rotation in Ligament Balanced Knee ArthroplastyThe Journal of Arthroplasty, 2013
- Internal Rotation of the Tibial Component is Frequent in Stiff Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2011
- Is the Anterior Tibial Tuberosity a Reliable Rotational Landmark for the Tibial Component in Total Knee Arthroplasy?The Journal of Arthroplasty, 2011
- Gap Balancing versus Measured Resection Technique for Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2010
- Stress analysis of the anterior tibial post in posterior stabilized knee prosthesesJournal of Orthopaedic Research, 2007
- Synchronisation of tibial rotational alignment with femoral component in total knee arthroplastyInternational Orthopaedics, 2007
- Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2005
- Rotational Constraint in Posterior-Stabilized Total Knee ProsthesesClinical Orthopaedics and Related Research, 2003
- The Effects of External Torque on Polyethylene Tibial Insert Damage PatternsClinical Orthopaedics and Related Research, 2003
- Rotational Landmarks and Sizing of the Distal Femur in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1996