Deviation Analysis of C1–C2 Transarticular Screw Placement Assisted by a Novel Rapid Prototyping Drill Template
Authors:
- Zhen-Shan YuanZYZhen-Shan Yuan
- Christopher K. KeplerCKChristopher K. Kepler
- Todd J. AlbertTATodd J. Albert
- Jian-Bing YuanJYJian-Bing Yuan
- Wei-Xin DongWDWei-Xin Dong
- Xiao-Yang SunXSXiao-Yang Sun
- Cheng-Tao WangCWCheng-Tao Wang
- 1 July 2014
- journal article
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 27 (5) , E181-E186
Abstract
Cadaveric study. The aim of this study was to develop and validate the accuracy of a novel navigational template for C1-C2 transarticular screw (C1C2TAS) placement in cadaveric specimens. Currently, C1C2TASs are primarily positioned using a free-hand technique or under fluoroscopic guidance. Screw placement is challenging owing to the small size of the C2 isthmus, which places technical demands on the surgeon. Screw insertion carries a potential risk of neurovascular injury, magnifying the importance of using a precise technique for screw insertion. Computed tomography (CT) scans with 0.625-mm wide cuts were obtained from the 32 cadaveric cervical specimens. The CT data were imported into a computer navigation system. We developed 32 three-dimensional drill templates, which were created by computer modeling using a rapid prototyping technique based on the CT data. We constructed drill templates using a custom trajectory for each level and side based on specimen anatomy. The drill templates were used to guide establishment of a pilot hole for screw placement. The entry point and angular direction of the intended screw positions and inserted screw positions were measured by comparing postoperative and preoperative images after the coordinate axes were synchronized. The average displacement of the entry point of the left and right C1C2TAS in the x-, y-, and z-axis was 0.13±0.90 mm, 0.50±1.50 mm, and -0.22±0.71 mm on the left, and 0.21±1.03 mm, 0.46±1.55 mm, and -0.29±0.58 mm on the right. There was no statistically significant difference in entry point and direction between the intended and actual screw trajectory. The small deviations seen are likely due to human error in the form of small variations in the surgical technique and use of software to design the prototype. This technology improves the safety profile of this fixation technique and should be further studied in clinical applications.Keywords
This publication has 10 references indexed in Scilit:
- Feasibility of C2 Translaminar Screw as an Alternative or Salvage of C2 Pedicle Screws in Atlantoaxial InstabilityJournal of Spinal Disorders & Techniques, 2012
- Safety of Cervical Pedicle Screw Insertion in ChildrenSpine, 2012
- Biomodeling as an Aid to Spinal InstrumentationSpine, 2005
- Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patientsJournal of Neurosurgery: Spine, 2005
- Posterior C2 Fixation Using Bilateral, Crossing C2 Laminar ScrewsJournal of Spinal Disorders, 2004
- Breakage of the Cranial Pinholder of the Patil Stereotactic SystemNeurosurgery, 2002
- Computer-assisted spine surgeryEuropean Spine Journal, 2000
- Posterior C1-C2 Transarticular Screw Fixation for Atlantoaxial ArthrodesisNeurosurgery, 1998
- The anatomical suitability of the C1–2 complex for transarticular screw fixationJournal of Neurosurgery, 1996
- Stable Posterior Fusion of the Atlas and Axis by Transarticular Screw Fixation1987